beautypg.com

Self diagnostics display – Davey Speedman Compact Constant Water Pressure Systems User Manual

Page 12

background image

12

Self Diagnostics Display

Should the Speedman Compact controller shut down unexpectedly, check

the controller screen for fault diagnostics information. The display will also

provide status information during normal operation.

MESSAGE

MESSAGE MEANING

PUMP STATE

WHAT TO DO

Disabled.........

• Controller engaged but

not engaged for electro-
pump checking

Off

• Repeat the start-up

procedure, setting ON/
OFF = 1

Active.........

• Controller is checking the

pressure

• Pressurised system

Off

Active..1.0.0...

• Controller is checking the

pressure

• Pressurised system

On

Active (leakage)

• Controller is checking the

pressure

• The system is leaking

Off

• Attempt to eliminate the

cause of the faulty sealing
of the plumbing system

Low ACMain......

• The power supply voltage

is too low (under 170 Vac)

• Automatic reset

Off

• Check the electrical

system and reset the
values to the range
as envisaged for the
controller

High ACMain......

• The power supply voltage

is too high (above 270
Vac)

• Automatic reset

Off

• Check the electrical

system and reset the
values to the range
as envisaged for the
controller

• Check if there is air in

pump and eliminate it

Short ph-ph-gnd.

• A phase/phase short

circuit or a phase/earth
short circuit has been
found on the pump motor

• Automatic and

programmable reset

• Set at the factory

for 5 attempts at
resetting every 10 sec;
if unsuccessful, the
system will remain in a
permanently locked state

Off

• Eliminate the short-circuit
• Check the correct motor

insulation

Reset:
1 Disconnect the power

supply

2 Wait for the display to

switch off

3 Restore the power supply