10

MAINTENANCE

The only regular attention your new pump set requires is to check the pressure tank’s air charge every 6 months.
This can be checked at the air valve with a tyre gauge. Do not charge tank to a higher pressure than 15 kPa below cut-in
pressure setting.

To check air pressure in tank:
1. Switch off pump.
2. Open outlet nearest to pump to release water pressure.
3. Remove air valve cap from top of Supercell tank and charge tank to correct pressure using air pump and check with

tyre gauge.

4. Reprime system and switch on.

*Standard settings. Can be adjusted to suit site conditions.

Pressure Settings

Pressure Settings*

Tank

Cut-in

Cut-out

Pressure

Pump

Motor

Standard Tank

kPa

kPa

kPa

VM5-5

1.1

HP24+

200

450

185

VM5-6

1.1

HP24+

300

550

285

VM5-7

1.5

HP24+

300

650

285

VM5-8

1.5

HP24+

300

700

285

VM10-4

1.5

HP24+

300

400

285

VM10-5

2.2

HP24+

350

500

335

VM10-6

2.2

HP24+

400

600

385

VM10-7

3

HP24+

500

700

485

VM16-3

3

HP24+

250

400

235

VM16-4

4

HP24+

350

550

335

VM16-6

5.5

HP24+

450

650

435

NOTE: Your pump is designed to operate as an automatic pressure system.
The pressure tank will require a specific precharge air pressure dependent upon model.
While your pressure tank may have been precharged in manufacture, the precharge pressure should
be checked upon installation and every 6 months thereafter. Follow the instructions on the tank. As a
guide, the precharge settings are listed below:–