4/1/08
Instruction / Installation Sheet
DataComm Electronics Home Command Center Models
70-0016 and 70-0017
Additional Cable Rough-In
For other data, security, network or other low voltage applications install appropriate
cables from each location leaving enough overage on each end so as to allow easy
installation and mark all cable ends with necessary information.
Each cable run should comply with all codes and good wiring practices should be
followed at all times.
Grounding
A grounding cable is to be run from the ground screw provided on the panel to the
electrical grounding for the dwelling.
Duplex Receptacle
Remove knockout in bottom of the panel.
Install UL approved receptacle box.
Run proper wires (according to code) to the receptacle box.
Install UL approved receptacle rated 125 VAC.
Install receptacle cover.
Insure that all work in done by a licensed electrical contractor.
Install Cover
Install the hinged cover using screws and locations provided for in the panel.
CAUTION
Never install telephone wiring during lighting storms.
Never install telephone jacks in wet locations unless the jack is specifically designed
for wet locations.
Never touch un-insulated wires or terminals unless the telephone line has been
disconnected at the network interface.
Use caution when installing or modifying telephone lines.
IMPORTANT INSTRUCTIONS
Read and understand all instructions.
Follow all warnings and instructions marked on the product.
Do not use this product near water, for example near a bath tub, wash bowl, kitchen
sink, or laundry tub, in wet a basement, or near a swimming pool.
Never push objects of any kind into this product through cabinet slots as they may
touch dangerous voltages.
SAVE THESE INSTRUCTIONS.
THE HOME COMMAND CENTER IS A DISTRIBUTION PANEL FOR LOW-VOLTAGE
WIRING SYSTEMS. IT IS NOT DESIGNED TO BE USED AS AN AC POWER
DISTRIBUTION PANEL.
USE ONLY CLASS 2 POWERED OR PASSIVE DEVICES.
ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT
ETL LISTED
CONFORMS TO
UL STD 1863
ANSI/UL STD 60950-1
CERTIFIED TO
CAN/CSA STD C22.2 NO 60950-1
3026001
ETL LISTED
HOUSEHOLD
BURGLAR-ALARM
SYSTEM UNITS
CONFORMS TO UL STD 1023