DataComm 70-0023 4X6 Phone for Data Module User Manual
DataComm For Home
3/13/08
Instruction / Installation Sheet
DataComm Electronics 4x6 Phone Module with
4 Port Passive Data 70-0023
Step 1
Align the mounting pins with holes in the back of the HCC panel and lock
module into place.
Pull the Cat 5 or higher rated cables into the HCC panel from one of the
side knockouts.
Install Cat 5 or higher rated cables from each location in the house to the
8-port passive data module. Match the color-coding of the wires to the
colors on the 110 IDC connectors.
The wires should be punched down, using an industry standard punch-
down tool, to the 110 IDC connectors following the T568A wiring
configuration as shown below.
Step 2 Telephone
Pull the telephone wires into the HCC panel from one of the side
knockouts.
Install the cable from the telephone company demarcation point to the
110 IDC marked from Telco.
Install the twisted pair cables from each location in the house to the
remaining 110 IDC connectors. Match the color-coding of the wires to the
colors on the 110 IDC connectors.
The wires should be punched down, using an industry standard punch-
down tool, to the 110 IDC connectors following the T568A wiring
configuration as shown below.
Line 1 is Blue, Line 2 is Orange, Line 3 is Green and Line 4 is Brown.
A RJ31X port is provided for line 1 seizure by security system.
White / Blue
Blue
White / Orange
Orange
White / Green
Green
White / Brown
Brown
INSTRUCTIONS ARE CONTINUED ON THE BACK SIDE OF THIS PAGE