DataComm 70-0022 1X6 Coaxial 4X6 Phone Module with 4 Port Passive Data User Manual

Page 2

background image

3/14/08 Rev. 1

Instruction / Installation Sheet

DataComm Electronics 1x6 Coax 4x6 Phone 4 Data Module 70-0022

Installation of 4 Port Data Ports

 Pull the Cat 5 or higher rated cables into the HCC panel from one of the

side knockouts.

 Install Cat 5 or higher rated cables from each location in the house to the

4-port passive data ports. Match the color-coding of the wires to the
colors on the 110 IDC connectors.

 The wires should be punched down, using an industry standard punch-

down tool, to the 110 IDC connectors following the T568A wiring
configuration as shown on previous page.

CAUTION

Never install telephone wiring during lighting storms.

Never install telephone jacks in wet locations unless the jack is

specifically designed for wet locations.

Never touch un-insulated wires or terminals unless the telephone

line has been disconnected at the network interface.

Use caution when installing or modifying telephone lines.

IMPORTANT INSTRUCTIONS

Read and understand all instructions.
Follow all warnings and instructions marked on the product.

Do not use this product near water, for example near a bath tub,

wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a
swimming pool.

SAVE THESE INSTRUCTIONS.

ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT

ETL LISTED

CONFORMS TO

UL STD 1863

ANSI/UL STD 60950-1

CERTIFIED TO

CAN/CSA STD C22.2 NO 60950-1

3026001