2 precautions, 3 alignment with distance measurement – Nexo RS User Manual
Page 40
Page 40/54
RAY
SUB
S IMPLEMENTATION
RS18 REFERENCE POINT IN OMNI MODE
RS18 REFERENCE POINT IN DIRECTIONAL MODE
7.4.2 Precautions
It is common to use the AUX send of a mixing desk to drive the Sub section of a PA system. This gives
the mixing engineer more flexibility to set the level of the subbass relative to the main PA, apply special
effects, or to use a different EQ on the Sub. However, it also raises some serious issues for the
performance & safety of the system (mostly time alignment).
At NEXO, great care is taken to design optimum phase alignment from one octave above to one octave
below the crossover frequency point. By doing so, drivers are working perfectly together and providing
the best efficiency possible. It is then up to the user to adjust the delay on the NX TDControllers to
match the physical path difference of the different systems. It is thus possible to get a well adjusted
system, even without measuring instruments.
If RS18s are driven form an AUX output, NX TDController is fed with two signals coming from different
sources. If those two sources (MAIN output & AUX send) are not exactly in phase, delay is introduced
into the crossover between main system and RS18s. It is then mandatory to use proper measurement
tool to optimize phase response.
IMPORTANT
- Before using different outputs of a mixing desk, ensure that MAIN and SUB outputs are
in phase;
- Never add additional low pass filtering on the SUB output or high pass filtering on the
MAIN output;
- Always apply identical processing (EQ etc…) on both outputs, so that the phase
relationship between MAIN and SUB is not altered;
7.4.3 Alignment with distance measurement
The fastest way to align RS18 arrays to a main system is simply to measure distance difference from
listening point to RS18 and main system reference points.
r
1
being the distance from main array to listener position, and
r
2
being the distance from RS18 to
listener position, the distance difference is then
r
1
–
r
2
(specified meters or feet).
•
r
1
>
r
2
, the delay should be set on the RS18 TDcontroller channel.
•
r
1
<
r
2
, the delay should be set on the main system TDcontroller channel
• ∆t = (
r
1
-
r
2
)/C
gives conversion from distance to delay
r
1
,
r
2
in meters, C = 343 m/s.