beautypg.com

Nexo RS User Manual

Page 37

background image

RAY

SUB

S IMPLEMENTATION

Page

37/54

“FACE TO FACE“ CONFIGURATION

7.2.3 RS18s

arrays

IMPORTANT

RS18s arrays must be installed with bumper set horizontally and all cabinets at 0°.

Flying RS18s columns can significantly improve low frequency coverage in the vertical plane, and
therefore over audience depth provided height is sufficient.

A 10 RS18 cluster flown at 10m/30ft will provide a +/- 3dB pressure level deviation at 100Hz over an
audience area 75m/200ft deep while maintaining 15 to 20dB attenuation on stage (see figure below).

10 RS18 CLUSTER OVER 75M/200FT

7.3 Steered RS18s arrays

7.3.1 Steering

technique

RS18s arrays must be flown vertically with bumper set horizontally and all cabinets at 0°.

Coverage adjustments can be efficiently implemented through the “steering” technique, which consists
in implementing delays in cabinets to tilt coverage up or down.

This manual is related to the following products: