Symptoms
Probable Cause
Recommended Action
Pump will not start.
Electrical supply.
Check power to motor.
Check the circuit breaker is set.
Check the correct fuse is being used.
Starter thermal
overload tripped.
Check overload in starter (if applicable).
Investigate cause of problem.
Internal motor
thermotrip activated.
Wait for thermotrip to cool and auto-
reset. Investigate cause of problem.
Pump runs, but no
liquid.
Air locked.
Bleed pipework and pump to clear air.
No liquid supply.
Check the supply valves are turned on.
Check outlet not restricted or blocked.
Connections
reversed.
Check liquid connections are on the right
way round.
No flooded suction.
Check the pump has a flooded suction
and is primed.
If a suction lift exists fit a Stuart footvalve/
strainer and ensure suction is airtight.
Prime the pump and suction pipe (see
commissioning section).
- Monsoon U4.5 bar Twin (28 pages)
- Monsoon U4.5 bar Single (28 pages)
- Monsoon S4.5 bar Single (24 pages)
- Monsoon Extra U5.0 bar Single (20 pages)
- Monsoon Extra U4.5 bar Single (24 pages)
- Monsoon Extra S1.4 bar Single (16 pages)
- Monsoon Extra S4.5 bar Single (20 pages)
- Monsoon Extra 3.6 bar PS (20 pages)
- Monsoon Extra 4.7 bar Presure Set (20 pages)
- Showermate U2.6 bar Single (28 pages)
- Showermate S2.6 bar Single (24 pages)
- Showermate eco S2.0 bar Single (20 pages)
- U3.3 bar Single (20 pages)
- S3.3 bar Single (20 pages)
- S2.0 bar Single (20 pages)
- Flomate Mains Boost (16 pages)
- WC3 Macerator Pumps (20 pages)
- Pumps - Lifting Station (16 pages)
- Multistage xxx-60 Series (16 pages)
- CH 4-60 FL (20 pages)
- CH 4-60 B (20 pages)
- Submersible Supersub VA (16 pages)
- Submersible Supervort (16 pages)
- Submersible Diver 35 & 45 (16 pages)
- Submersible Diver 35 & 45 Boostamatic (24 pages)
- Jet Pump 45 (16 pages)
- Jet Pump 45 B (20 pages)
- Jet Pump 45 PS (16 pages)
- PH 45 TS S (16 pages)
- PH 45 ES (16 pages)
- Kennet KF2 (20 pages)
- Kennet 2 Boostamatic (20 pages)
- Self Priming X201 Centrifugal (20 pages)
- 12/50 24 V (12 pages)
- Stuart Flange SE (1 page)
- Float Switch (16 pages)
- Floating Switches (6 pages)
- TFL Automatic Flow Switch (20 pages)
- LFL Automatic Flow Switch (20 pages)
- Boostamatic2/T12-2 (20 pages)
- ES Boostamatic 6000 (20 pages)
- Self Priming Jet 40 Centrifugal (16 pages)
- Self Priming Jet 90 Centrifugal (16 pages)
- Techflo TP 60SNH (28 pages)
- Techflo TP 55S (20 pages)