Stuart Turner Techfo TP 50T User Manual
Page 13

- 13 -
Cont ...
4.21
Fuse: The following fuse size should be used with the appropriate pump:
Model
Fuse Size (AMPS)
All Models
5
4.22
Internal Wiring
Do not remove terminal box cover. No user serviceable parts
inside terminal box. Any service work involving the removal of the
terminal box cover must only be undertaken by Techflow Products
or by one of their approved repairers, or similarly qualified
persons in order to avoid a hazard.
There are no user serviceable electrical items within the pump.
4.23
Supply Cord Replacement
If the supply cord is damaged, it must be replaced by Techflow
Products or by one of their approved repairers, or similarly
qualified persons in order to avoid a hazard.
4.24
Supply Cord Extension
The pumps are fitted with a supply cord to the following specification:-
HO5VV-F3 G 0.75 mm² - 6 Amp rated cable.
If the supply cord is to be extended, a cord of the same specification should be
used. Any connections or junction boxes used should be specifically suited for
the application and installed in accordance with the manufacturers instructions.