Stuart Turner Techfo TP 50T User Manual
Page 10
![background image](/manuals/360753/10/background.png)
- 10 -
Cont ...
3.13
Pumps supplied with flexible inlet and outlet hoses:
Flexible pipes are supplied with this pump variant. The pump inlet and outlet
ports are threaded G ¾ male. These ports are provided with a flat sealing face
suitable for use with an appropriately sized flat faced fitting and fibre or rubber
washer. Ensure a watertight seal is achieved when the pump is both stationary
and
running.
1. Hoses incorporating integral isolating
valves should be applied to the inlet
side of pump to satisfy servicing
requirements.
2. Standard hoses with no integral
isolating valve should be applied to the
outlet side of pump.
3. Use correct tool for opening and closing
integrated isolating valve to prevent
damage. Please note these valves are
of quarter turn design, rotate clockwise
to close and anti-clockwise to open.
Failure to comply to these instructions
could lead to valve damage.
Fig. 10
Close
Open