beautypg.com

General, Limits of application – Stuart Turner LFL Automatic Flow Switch User Manual

Page 4

background image

- 4 -

Cont ...

*Note: Max working pressure is the maximum pressure that can be applied to the

pump internal casing under any installation conditions.

General:

All models use a flow switch assembly which is directly connected to the pump discharge

port. The wetted materials of construction are brass, stainless steel, strontium ferrite, nitrile
and acetal.

All models are supplied with a mains connecting lead and resilient mounting foot.

LIMITS OF APPLICATION

Model

Max.

Liquid

Temp.

o

C

Min.

Liquid

Temp.

o

C

Max.

Ambient

Air Temp

o

C

Inlet

Head

(Suction)

Max.

No of

Starts/h

**Max.

Working

Pressure

kPa (bar)

Max.

Inlet

Head

(m)

Max.

Head (Pump

Closed Valve)

(m)

Cut in

Flow

(l/min)

RGFL4000

80

4

40

Flooded

60

600 (6)

14

30

0.6

RGFL6000

80

4

40

Flooded

60

600 (6)

14

40.6

0.6

RGDFL6000

80

4

40

Flooded

60

600 (6)

14

41.6

0.6

ESFL4000

80

4

40

Flooded

60

600 (6)

14

29.5

0.6

ESFL6000

80

4

40

Flooded

60

600 (6)

14

40

0.6

KFL9-2

65

4

40

Flooded

60

600 (6)

14

9

1

KFL12-2

65

4

40

Flooded

60

600 (6)

14

13.9

1

LFL5-4S

65

4

40

Flooded

60

700 (7)

14

44

1

LFL7-4S

65

4

40

Flooded

60

700 (7)

14

48

1