Stuart Turner PH 35 TS User Manual
Page 8

- 8 -
Cont ...
Supply Cord Replacement:
The supply cord and internal wiring within the terminal box are routed and
secured to ensure compliance with the electrical standard EN 60335-1. It
is essential that prior to any disturbance of this internal wiring, all cable
routing and securing details are carefully noted to ensure re-assembly to
the same factory pattern is always maintained.
If the supply cord is to be changed or is damaged, it must be replaced with a special cord
assembly available from Stuart Turner or one of their approved repairers.
On disassembly note the cord retention and routing system. Re-assemble to the same
pattern.
For information on cable connection consult the wiring diagram and cable gland fitting
instructions.
Cable Gland Fitting Instructions:
To enable correct assembly of the cable gland the ‘O’-ring (Fig. 12 item 1) must be
placed over the cable before the clamping insert (Fig. 12 item 2) can be tightened.
Note: Cable diameter range:- 6.5 mm to 9.5 mm.
Supply Cord Extension:
The pumps are fitted with a supply cord to the following specification:-
All models . . . . . . . . . . . . . . . . . HO5VV-F3 G 0.75 mm² - 6 Amp rated cable.
If the supply cord is to be extended, a cord of the same specification should be used.
Any connections or junction boxes used should be specifically suited for the application
and installed in accordance with the manufacturers instructions.