Supply Cord Replacement:

The supply cord and internal wiring within the terminal box are routed and
secured to ensure compliance with the electrical standard EN 60335-1. It
is essential that prior to any disturbance of this internal wiring, all cable
routing and securing details are carefully noted to ensure re-assembly to
the same factory pattern is always maintained.

If the supply cord is to be changed or is damaged, it must be replaced with a special cord

assembly available from Stuart Turner or one of their approved repairers.

On disassembly note the cord retention and routing system. Re-assemble to the same

pattern.

For information on cable connection consult the wiring diagram and cable gland fitting

instructions.

Cable Gland Fitting Instructions:

To enable correct assembly of the cable gland the ‘O’-ring (Fig. 12 item 1) must be

placed over the cable before the clamping insert (Fig. 12 item 2) can be tightened.

Note: Cable diameter range:- 6.5 mm to 9.5 mm.

Supply Cord Extension:

The pumps are fitted with a supply cord to the following specification:-

All models . . . . . . . . . . . . . . . . . HO5VV-F3 G 0.75 mm² - 6 Amp rated cable.

If the supply cord is to be extended, a cord of the same specification should be used.
Any connections or junction boxes used should be specifically suited for the application
and installed in accordance with the manufacturers instructions.