3 ELECTRICAL INSTALLATION / EARTHING

3.11

Regulations: The electrical installation must be carried out in

accordance with the current national electrical regulations and installed

by a qualified person.

3.12

Safety: In the interests of electrical safety a 30 mA residual current

device

(

R.C.D. not supplied) should be installed in the supply

circuit. This may be part of a consumer unit or a separate unit.

3.13 Before starting work on the electrical supply ensure power supply is

isolated.

3.14

DO NOT allow the supply cord to contact hot surfaces, including the

motor shell, pump body or pipework. The cord should be safely

routed and secured by cable clips.

3.15

Earthing: This appliance must be earthed via the supply cord, which must be

correctly connected to the earth point located in the terminal box.

3.16

Electrical Connection: The pump is provided with a factory fitted supply cord

and plug. This must be connected to the mains supply via a 13 Amp double pole

switched, socket outlet in compliance with BS 1363-2. The socket outlet should

be mounted in an easily accessible position and should be labelled if confusion

is possible, to allow easy identification of the pump isolating switch.

3.17

Wiring of connection unit:

WARNING: A plug with bared flexible cords is hazardous if
engaged in a live socket outlet.

The moulded plug fitted to this appliance is not waterproof - keep dry.

The supply cord is factory fitted with a moulded plug incorporating a fuse, the

value of which is indicated on the pin face of the plug. Should the fuse need to

be replaced, an ASTA approved BS 1362 fuse must be used of the same rating,

marked

thus, . If the fuse cover is detachable, never use the plug with

the cover omitted. If a replacement fuse cover is required, ensure it is of the

same colour as that visible on the pin face of the plug (i.e. red or orange).

The wires in the mains lead are coloured in accordance with the following code:

Green and Yellow: Earth

Blue: Neutral

Brown: Live

As the colours of the wires in the mains lead of this appliance may not correspond

with the coloured markings identifying the terminals in your connection unit

proceed as follows:

The wire which is coloured green and yellow must be connected to the terminal

in the connection unit which is marked with the letter E or by the earth symbol:

or coloured green or green and yellow.

The wire which is coloured blue must be connected to the terminal which is

marked with the letter N or coloured black or blue.

The wire which is coloured brown must be connected to the terminal which is

marked with the letter L or coloured brown or red.