Stuart Turner S1.3 bar Twin User Manual
Page 14

- 14 -
Cont ...
6.13 No other routine maintenance is required.
6.14
Water scale: As water is heated scale deposits are released in areas of hard
water, scale can cause the mechanical seal to stick if left without use for long
periods. The pump must be run for at least 5 minutes every four weeks to
“exercise” all working parts. Run on cool water. See Section 7 - Technical
Specification for note on water temperature. This particularly applies to guest
bathrooms used infrequently.
6 MAINTENANCE
6.11 Turn off water supplies to the pump and release pressure by
opening water outlets before attempting maintenance.
6.12
Inlet Strainer: The inlet strainers may require periodical cleaning. The frequency
of this operation is dependent upon installation conditions.
The strainer is located in the inlet assembly of the pump casing and is removed
as
follows:-
a) Isolate pump electrically.
b) Release all system pressure.
c) Isolate hot and cold water supplies via the integral pump isolating valve
located in the flexible hoses and release hoses by holding the collets
connected to the pump on the inlet side (see Section 3 - Pump Connections).
d) The stainer is now visible and can gently be prised out of the inlet connection.
Clean
thoroughly.
e)
Refit
strainer.
f) Re-connect flexible hoses (see Section 3 - Pump Connections).
g) After maintenance is completed refer to Section 5 - Commissioning section for
instructions on re-starting pump.
Strainer
Pump inlet
Fig. 9