beautypg.com

Stuart Turner S1.3 bar Twin User Manual

Page 10

background image

- 10 -

Cont ...

3. Check in the mouth of the fitting that ‘O’-ring, washer and collet are in

position.

4. Push pipe firmly into fitting, until pencil mark is level with the top of the collet

and the pipe stop resistance is felt. Pull on pipe to check it is secure and

correctly

fitted.

5. To break the joint, push pipe firmly into fitting, hold collet down and gently

remove pipe. If the system has been filled with water care should be taken

to isolate pump and towels used to absorb spilled water.

3.13

Typical Low Level Installation: In certain installations it may be necessary to

install a 90° bend on the inlet or outlet connections of the pump before the

flexible hose to accommodate a low level installation. For this purpose use a

22 mm stem elbow (not supplied).

If you have any concern either about using push-in fittings or should the joint
leak on final test isolate the water supplies and contact PumpAssist on
0844 98 000 97.

Fig. 6

Body

Collet

Washer

‘O’-Ring

Pipe Stop

Hose

Isolating Valve

Fig. 7

Inlet

Outlet

22 mm stem elbows

This manual is related to the following products: