COMMAND:
Byte:

Description:

St

0x21

Zn

Zone number

Cc

0x1F

Data1

0x00 – Deactivate mute line
0x01 – Activate mute line

Dl

0x01

Et

0x0D

RESPONSE:
Byte:

Description:

St

0x21

Zn

Zone number

Cc

0x1F

Ac

Answer code

Dl

Data length

Data1

Relay state

Et

0x0D

activate/deactivate the mute lines (0x1f)
Activate/deactivate the mute lines on the designated zone.

example
Command/response sequence to activate the mute relays:

Command:

0x21 0x01 0x1F 0x01 0x0D

Response:

0x21 0x01 0x1F 0x00 0x01 0x0D

report amplifer temperature status (0x27)
Report the temperature status of the various zones amplifiers.

example
Command/response sequence to request the temperature of zone 1 where

temperature is too high:

Command: 0x21 0x01 0x27 0x01 0xF0 0x0D

Response:

0x21 0x01 0x27 0x00 0x01 0x01 0x0D

Note: As each amplifier powers a pair of zones (1&2, 3&4 , 5&6) the

temperature status of zones 1 and 2 is the same value.

COMMAND:
Byte:

Description:

St

0x21

Zn

Zone number

Cc

0x27

Dl

0x01

Data

0xF0 – Request temperature status

Et

0x0D

RESPONSE:
Byte:

Description:

St

0x21

Zn

Zone number

Cc

0x27

Ac

Answer code

Dl

0x01

P2

0x00 – Temperature OK
0x01 – Over temperature

Et

0x0D