Empty used fluid tank, Filter maintenance – MAHLE RTI BFX-2 User Manual
Page 9

Page 8
Empty Used Fluid Tank
1. Disconnect the fluid line coupler and the electrical float switch cable on the Used Fluid Tank.
2. Remove cap on Used Fluid Tank (turn counterclockwise).
3. Empty used fluid into an appropriate bulk waste container.
4. Replace cap on Used Fluid Tank (turn clockwise).
5. Connect fluid line coupler and the electrical float switch cable.
Follow all federal and local laws and regulations when disposing of hazardous material.
Filter Maintenance
The BFX-2V has six filters to prevent debris from entering internal components.
New Fluid Filter: Filters fluid from the New Fluid Bottle. If the
fluid flow seems slow while trying to fill the
master cylinder - check and clean this filter.
This filter can be accessed through the front
door on the top of the BFX-2V. Remove
screws and gently raise the door to access
the filter.
Unscrew the filter cover and clean the
screen as required.
Vacuum Filter:
Filters fluid in the five vacuum hoses. A filter
is mounted in-line on each of the hoses. If
the fluid flow seems slow from the bleeders -
check and clean these filters.
These filters can be accessed through the
rear door on the top of the BFX-2V. Remove
the two thumb screws and lift the door. The
filters will be seen about 12 inches below
where the hoses go through the panel
inside. Remove hoses from both ends of the
filter and try clearing the filter with
compressed air.
New Fluid Filter
56
0-8
037
9-0
0
Hose
Vacuum Filter