13 troubleshooting (continued) – MAHLE RTI NTO-200 (REV A) User Manual
Page 14
![background image](/manuals/360623/14/background.png)
13
TROUBLESHOOTING (Continued)
Fault
Probable Cause
Solution
Compressed air supply does
not meet specified
requirements of ISO 8573-1:
2001 Class 3.-.3
It is not allowed to feed
liquid/aerosol/condensate
water or oil into NTO-200.
Check the following:
1.) Compressor operating correctly
and fully maintained.
2.) No contaminants near
compressor's intake.
3.) Compressed air system has
suitable filtration and is correctly
maintained.
Inlet pressure too low or too
high.
Ensure inlet pressure is within limits
specified under “Technical
Specification” section.
Reduced Purity of
nitrogen
Cartridge nearing end of life.
Replace cartridge
Internal blockage
Contact NTO-200 supplier.
Cartridge not installed
correctly.
Ensure cartridge correctly fitted in grip
Tire pressure does
not fall when
ON/OFF button
held in.
Internal fault
Contact NTO-200 supplier.
Cartridge not installed
correctly.
Ensure cartridge correctly fitted in grip
Pressure
continually high.
There is internal component
fault
Contact NTO-200 supplier.