beautypg.com

Sterling QVES User Manual

Page 30

background image

30

POWER VENTED INDOOR DUCT FURNACE

UNIT NUMBER DESCRIPTION

Digit #1, 2 - Unit Type [UT]

D2 - Power Vented Duct Furnace
D6 - Side Service Power Vented Duct Furnace

Digit #3, 4, 5 - Capacity [CA]

100 - 100,000 BTU/HR
125 - 125,000 BTU/HR
150 - 150,000 BTU/HR
175 - 175,000 BTU/HR
200 - 200,000 BTU/HR
225 - 225,000 BTU/HR
250 - 250,000 BTU/HR
300 - 300,000 BTU/HR
350 - 350,000 BTU/HR
400 - 400,000 BTU/HR

Digit #6 - Furnace Type [FT]

A - Right Side Access (Standard)
B - Left Side Access

Digit #7 - Heat Exchanger Construction Material [FM]

1 - Aluminized Steel
2 - 409 Stainless Steel
3 - 321 Stainless Steel

Digit #8 - Gas Type [GT]

N - Natural Gas
P - Propane Gas (LP)
K - Natural Gas w/100% Shutoff

Digit #9 - Ignition Control [IC]

2 - Spark Ignition

Digit #10 - Altitude [AL]

A - 0–1,999 ft.

J - 8,000–8,999 ft.

B - 2,000–2,999 ft.

K - 9,000–9,999 ft.

C - 3,000–3,999 ft.

L - 10,000–10,999 ft.

D - 4,000–4,999 ft.

M - 11,000–11,999 ft.

F - 5,000–5,999 ft.

N - Local Gas Supplier Derate

G - 6,000–6,999 ft. P

- Canadian High Altitude 2,000–4,500 ft.

H - 7,000–7,999 ft.

Digit #11 - Gas Control [GC]

A - Single Stage
B - Two Stage
H - Electronic Modulation w/Room Sensing
J - Electronic Modulation w/Duct Sensing
K - Electronic Modulation w/Duct Sensing & Room Ovrd. Stat
L - Electronic Modulation w/External 4-20 mA Input
N - Electronic Modulation w/External 0-10 VDC Input

Digit #12 - Supply Voltage [SV]

1 - 115/1/60 5

- 230/3/60

2 - 208/1/60 6

- 460/3/60

3 - 230/1/60 7

- 575/3/60

4 - 208/3/60

Z - Special

Note: Supply Voltages [SV] 2-7 include fi eld mounted step down transformer.

Digit #13 - Motor Type [MT]

0 - None/Not Applicable

Digit #14 - Motor Sizes [MS]

0 - None/Not Applicable

Digit #15 - Accessories [AS]

FACTORY INSTALLED

A8 - Input Derate

P4 - Terminal Block Wiring

P6 - Summer/Winter Switch

K4 - Fan Time Delay

K5 - Air Flow Prove Switch

S1 - 409 Stainless Steel Burners

S3 - 409 Stainless Steel Flue Collector

† FIELD INSTALLED (AS-____ )

† Field Installed Accessories are not included in the Unit Number. All Field Installed
Accessories are entered as a separate line item using the catalog number which utilizes
“AS” as a prefi x. i.e: A7 becomes AS-A7.

A7 - Pressure Regulator 1/2-2 psi

H5 - Low Ambient Control

F1 - 1-Stage T675A Ductstat M2-1 - Vent Caps (4 inch) (Unit Capacity 100-175)
F2 - 2-Stage T678A Ductstat

M2-2 - Vent Caps (5 inch) (Unit Capacity 200-250)

M2-3 - Vent Caps (6 inch) (Unit Capacity 300-400)

G1 - 1-Stage T87K Mercury Free Thermostat

M3-1 - Adaptors (5-4 inch) (Unit Capacity 100-175)

w/Subbase Kit
G2 - 1-Stage T87K Mercury Free Thermostat

P2 - Adjustable High Limit Switch

w/TG511A Guard Kit

P3 - Adjustable Fan Switch

G3 - 1-Stage T834N Mercury Free Thermostat

P5 - 24V SPST Relay-Specify Purpose

w/Fan Switch
G6 - Locking Thermostat Cover Q7 - Horizontal/Vertical Louvers
G8 - 1-Stage T6169C Line Voltage Stat
w/Subbase

S4 - 409 Stainless Steel Drip Pan

G9 - 1-Stage T822K Mercury Free
Thermostat



Digit

X X X X — 1 2 3 4 5 6 7 8 9 10

11

12

13

14

15 +

Item

Prefi

x

UT

CA FT

FM

GT

IC AL

GC

SV

MT

MS AS

(Internal use Only)

This manual is related to the following products: