WARNING

The washer-extractor should be connected to an individual branch

circuit not shared with lighting or other equipment.

4

Electrical Specifications WFF75, IWF074, IWF018, CWF074, CWF018

75 liters / 18 pounds

Boiler Fed/Steam Heat

Electric Heat

Code

Voltage

Cycle

Phase

Wire

Full
Load Amps

Recommended Circuit

Breaker (US-market)

AWG/mm2

kW Standard

Heating Elements

Full
Load Amps

Recommended

Circuit Breaker (US-

market)

AWG/mm2

US NON-US

US NON-US

N

440-480 50/60

3

3+PE

3

10

10

14/2.5

3x2 kW

12

15

16

14/2.5

P

380-415 50/60

3

3+N+PE

7

15

16

14/2.5

16

20

20

12/4.0

Q

200-240 50/60

3

3+PE

7

15

16

14/2.5

23

30

32

10/6.0

X

200-240 50/60

1/3

2/3+PE

7

15

16

14/2.5

N/A N/A

N/A

N/A

Alternative Electric Heat Options

N

440-480 50/60

3

3+PE

3x1.4 kW

N/A N/A

N/A

N/A

P

380-415 50/60

3

3+N+PE

13

15

16

14/2.5

Q

200-240 50/60

3

3+PE

18

20

20

12/4.0

X

200-240 50/60

1/3

2/3+PE

N/A N/A

N/A

N/A

N

440-480 50/60

3

3+PE

3x3 kW

N/A N/A

N/A

N/A

P

380-415 50/60

3

3+N+PE

21

30

32

10/6.0

Q

200-240 50/60

3

3+PE

30

40

40

8/10.0

X

200-240 50/60

1/3

2/3+PE

N/A N/A

N/A

N/A

N

440-480 50/60

3

3+PE

3x4 kW

20

30

25

10/6.0

P

380-415 50/60

3

3+N+PE

24

30

30

10/6.0

Q

200-240 50/60

3

3+PE

N/A N/A

N/A

N/A

X

200-240 50/60

1/3

2/3+PE

N/A N/A

N/A

N/A

Table 3

This manual is related to the following products: