3 optional specifications, Optional specifications -10, Optional specifications (others) – Yokogawa EJX210B User Manual
Page 97

<11. General Specifications>
11-10
IM 01C27C01-01EN
11.3 Optional Specifications
OPTIONAL SPECIFICATIONS (For Explosion Protected type)
Item
Description
Code
Factory Mutual (FM)
FM Intrinsically safe Approval
FS17
ATEX
ATEX Intrinsically safe Approval
KS27
Canadian Standards Association (CSA)
CSA Intrinsically safe Approval
CS17
IECEx
IECEx Intrinsically safe Approval
SS27
OPTIONAL SPECIFICATIONS (Others)
T07E.ai
Code
Description
Item
K1
Degrease cleansing treatment
Oil-prohibited use
D1
P calibration (psi unit)
Calibration units
*2
D3
bar calibration (bar unit)
(See table for Span and
Range Limits.)
D4
M calibration (kgf/cm
2
unit)
TF1
Diaphragm protection from sticky process fluid by FEP Teflon film attached with fluorinated oil.
Operation range: 20 to 150°C, 0 to 2 MPa (Not applicable for vacuum service).
Teflon film
*3 *4
A1
Inside of isolating diaphragms (fill fluid side) are gold plated, effective for hydrogen permeation.
Gold-plated diaphragm
*5
Painting
Material
certificate
For Flush
type
P
Amplifier cover only
X2
Anti-corrosion coating *
1
M3W
High Pressure side: Process flange, Block, Ring
*6 *8
Low Pressure side: Cover flange
M4W
High Pressure side: Process flange, Block, Ring
*7 *8
Low Pressure side: Cover flange, Process connector
M0E
High Pressure side: Process flange, Block, Pipe, Base
*6
Low Pressure side: Cover flange
M1E
High Pressure side: Process flange, Block, Pipe, Base
*7
Low Pressure side: Cover flange, Process connector
For Extended
type
K5
Degrease cleansing and dehydrating treatment
Oil-prohibited use
with dehydrating treatment
(Flange rating)
(Test pressure)
Pressure test/Leak test
Certificate
*9*10
T51
JIS 10K
2 MPa (290 psi)
T54
JIS 20K
5 MPa (720 psi)
T52
ANSI/JPI Class 150
3 MPa (430 psi)
T56
ANSI/JPI Class 300
8 MPa (1160 psi)
*11
T55
ANSI/JPI Class 300
7 MPa (1000 psi)
*12
Nitrogen (N
2
) Gas
*13
Retention time: one minute
M0W
High Pressure side: Process flange, Block
*6
Low Pressure side: Cover flange
M1W
High Pressure side: Process flange, Block
*7
Low Pressure side: Cover flange, Process connector
Color change
Coating change
*1:
Not applicable with color change option.
*2:
The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option code
D1, D3, and
D4.
*3:
Applicable for flush type (process connection style code
W.)
*4:
Applicable for flushing connection ring code
0.
*5:
Applicable for wetted parts material code
SW, SE, WW, WE, and HW.Consult Yokogawa in case gold-plated diaphragm is required
for low pressure side.
*6:
Applicable for Low Pressure Side Process connection code
0 and 5.
*7:
Applicable for Low Pressure Side Process connection code
1, 2, 3, and 4.
*8:
Applicable for flushing connection ring code
A, B, C, and D.
*9:
The unit on the certificate is always MPa regardless of selection of option code
D1, D3, or D4.
*10: A flushing connection ring will not be applied when conducting the pressure test or leak test.
*11: Applicable for flush type (process connection style code
W.)
*12: Applicable for extended type (process connection style code
E.)
*13: Pure nitrogen gas is used for oil-prohibited use (option code
K1 and K5.)