Burn-in, Ordering information – Toxalert CM203 User Manual
Page 4

CM 200 2/10 TMK
TOXALERT INTERNATIONAL, INC.,
P.O. BOX 159, MOUND, MINNESOTA 55364 (952) 472-4541 FAX (952) 472-4960
Visit our website at www. toxalert. com
3. BURN-IN:
Burn-In period allows sensor to stabilize before applying power to remote device(s) connected to models
CM202 & CM203.
1.) Be sure power is off to remote devices and monitor supply power is turned on.
2.) Allow sensor to burn-in for a minimum of 72 hours with power turned on to monitor. Monitor
may go in and out of alarm during burn-in.
3.) When 72 hours have elapsed, confirm remote device(s) wiring and turn power on to remote
devices.
4.) Status LED flashes on and off to indicate normal operation. If LED is on solid green or red;
please contact your local representative or TOXALERT INTERNATIONAL, INC. for
servicing.
ORDERING INFORMATION:
CM SERIES CARBON MONOXIDE MONITOR:
Model No.
Description
CM 201
Carbon Monoxide Monitor with single stage audible alarm.
CM 202
Carbon Monoxide Monitor with warning output relay and alarm
output relay.
CM203
Carbon Monoxide Monitor with warning output relay and alarm stage
audible alarm with silence switch.
OPTIONAL POWER SUPPLIES FOR CM200 SERIES:
Model No.
Description
CMP12U
Power Supply, 120 VAC to 12 VDC,
@ 300mA (Regulated) Unit Mounted.
CMP12M
Power Supply, 120 VAC to 12 VDC
@ 1.7 A (Regulated), Nema 1 Enclosure (for up to five units).
CM202 SHOWN WITH
CMP12U POWER SUPPLY
(Factory Mounted)
FIG. 2 MOUNTING DIMENSIONS