beautypg.com

Specifications, Ordering information, Your authorized watlow distributor – Watlow E-Safe Hybrid Relay Rev B User Manual

Page 4

background image

Declaration of Conformity

Series E-Safe Relay

Watlow Winona, Inc.
1241 Bundy Blvd.
Winona, MN 55987 USA

Declares that the following product:

Designation:

Series E-Safe

Model Numbers:

ES (20 or 40) - 3 (024, 120, 220) - ACCE

Classification:

Mechanical Relay, AC-51 Utilization
Category for

Resistive Loads. Installation

Category II, Pollution degree 2

Rated Voltage and Frequency:

Load 24-240 V~(ac) 50/60 Hz,
Control Signal 24 V~, 120 V~ or 200-240V~

Rated Power Consumption:

Load 20 A or 40 A depending on model.
Control Signal 15 VA Max.

Meets the essential requirements of the following European Union Directives by using the relevant
standards show below to indicate compliance.

89/336/EEC Electromagnetic Compatibility Directive

EN 60947-4-3

2000

Low-voltage switchgear and controlgear - Contactors and
motor-starters - AC semiconductor controllers and contactors
for non-motor loads. Industrial Immunity, Class B emissions.

EN 61000-4-2

1995

Electrostatic Discharge Immunity

EN 61000-4-3

1996

Radiated Field Immunity

EN 61000-4-4

1995

Electrical Fast-Transient / Burst Immunity

EN 61000-4-5

1 9 9 5 , A 1 : 1 9 9 6

Surge Immunity

EN 61000-4-6

1996

Conducted Immunity

EN 61000-4-11 1994

Voltage Dips, Short Interruptions and Voltage Variations Immunity

EN 61000-3-2

2000 ED.2.

Harmonic Current Emissions

73/23/EEC Low-Voltage Directive

EN 60947-4-3

2000

Low-voltage switchgear and controlgear- Contactors and
motor-starters - AC semiconductor controllers and contactors
for non-motor loads.

Raymond D. Feller III

Winona, Minnesota, USA

Name of Authorized Representative

Place of Issue

General Manager

February 2004

Title of Authorized Representative

Date of Issue

Signature of Authorized Representative

Ordering Information

(2145)

Part Number

E S _ _ - _ _ _ _ - _ _ _ _

Amperage

20 = 20 amp
40 = 40 amp

Number of Poles

3

= 3-pole

Control Voltage

024 AC = 24 V~
120 AC = 120 V~
220 AC = 220 V~

Label Options

00 = Standard Product
CE = With CE mark

Specifications

(2146)

Control Mode

Zero cross switching output

Form A outputs, without arcing

Cycle rate: 30 cycles per minute, maximum

Input Command Signal

24V~ (+10% / -10%) @ 0.375 Amperes

120V~ (+10% / -10%) @ 0.075 Amperes

220V~ (+15% / -20%) @ 0.041 Amperes

50/60 Hz

Input Surge current and pulse characteristics

24 volt input = 24 Amp surge, less than 10VA required (0.41 A)
120 volt input = 16 Amp surge, less than 12VA required (0.101 A)
220 volt input = 8 Amp surge, less than 14VA required (0.063 A)

Power factor approximate 0.58, 100 uSec pulse width or surge.
Note:
Do not use a RC snubber on the Esafe input or the temperature con-
trol command signal output

Output Rating

20A to 40A max. per pole into a resistive load,
model number dependent

208/240V, 50/60 Hz, phase to phase

3-pole

Leakage current: 0.5mA max.

Operating Life

1,000,000 switching cycles at maximum rating

Weight/Dimensions

Weight: 0.560 Kg (1.25 lb)

96.0 mm (3.78 in) high x 82.3 mm (3.24 in) wide
x 90.2 mm (3.55 in) deep

Terminals

Control input: Compression, accept 0.2 to 6 mm2 (# 22 -10 AWG)
wire, torque to 0.8 Nm (7 in-lbs) maximum

Output: Compression, accept 2.5 to 16 mm2 (# 14- 6 AWG) wire,
torque to 3.95 Nm (35 in-lbs) maximum

Operating Environment

Operating temperature, -30 to 55°C/-22 to 130°F

5 to 85% RH, non-condensing

Storage temperature, -40 to 85°C/-40 to 185°F

Mounting

Fits footprint of definite purpose relays and most 30 to 50 amp
mercury relays

Agency Approvals

UL® 508 listed, C-UL, File #E213822

Quality and Mission Statement:

Watlow Winona will be the world’s

best supplier of superior thermal solu-

tions by exceeding the expectations of

our customers, shareholders, and

employees.

Your Authorized Watlow Distributor: