beautypg.com

Installations, Installation requirements, Ps-b installation – Proface APL3000B - Node Box PC User Manual

Page 9

background image

9

• Be sure to connect pin number 5

(GND) of COM1 and COM2 (RS-232C)
to the host unit's Signal Ground
terminal.

• Be sure to confirm what settings will be

used by the other device and set the
slide switches accordingly. Failure to
do so can result in a unit malfunction or
damage.

• Whenever changing the PS-B

switches, be sure to first turn the PS-
B's power supply OFF. Failure to do so
can cause a PS-B malfunction.

• Connect the FG terminal line to the

shell.

• FG and SG terminals are internally

connected in the PS-B. When
connecting to another device, be sure
not to create an SG shorting loop in
your system.

Installations

1.

Installation Requirements

• For easier maintenance, operation, and

improved ventilation, be sure to install the
PS-B at least 50mm [1.97in.] away from
adjacent structures and other equipment.

120mm [4.72in.] space (minimum) is
necessary at the front for cable curve.

• Be sure that the surrounding air

temperature and the ambient humidity are
within their designated ranges.
(Surrounding air temperature: 0 to 50

°C,

Ambient humidity: 10 to 90%RH, Wet
bulb temperature: 39

°C or less)

Check the surrounding air temperature 30
mm [1.18 in.] away from the main unit.
Ex.: Horizontal mounting

.

• Be sure that heat from surrounding

equipment does not cause the PS-B to
exceed its standard operating temperature.

2.

PS-B Installation

• Determine the thickness of the board in

consideration of its strength. The

4

NC

No Connection

5

GND

Signal Ground

6

NC

No Connection

7

NC

No Connection

8

NC

No Connection

9

NC

No Connection

FG FG

Frame Ground
(Common with SG)

Pin

#

RS-485

Signal Name

Meaning

Unit:mm[in.]

50
[1.97]

120
[4.72]

50
[1.97]

Horizontal mounting (Front)

50
[1.97]

50 [1.97]

50 [1.97]

Horizontal mounting (Right side)

Wall mounting 1 (Front)

Wall mounting 1 (Right side)

Wall mounting 2 (Front)

Wall mounting 2 (Right side)

50
[1.97]

120
[4.72]

50
[1.97]

50
[1.97]

50

[1.97]

50

[1.97]

50
[1.97]

50

[1.97]

50
[1.97]

50 [1.97]

50 [1.97]

120
[4.72]

120
[4.72]

50 [1.97]

30
[1.18]

30
[1.18]

30
[1.18]

30
[1.18]

30
[1.18]

30
[1.18]

Unit:mm[in.]