beautypg.com

Sensing valves po check – Ross Controls 2_2 WAY WITH SENSING SERIES 27 User Manual

Page 2

background image

2

ROSS CONTROLS

®

Sensing Valves PO Check

2X O 0.26 (6.7)

B

A

C

Port PV

(pressure

verification)

5-pin M12

connector

Port 2

(outlet)

Port X-1

(1/8 external

pilot supply)

Port 1

(inlet)

2X O 0.53 (13.5)

B

A

C

Port PV

(pressure

verification)

Port Y-3

(pilot exhaust)

3-pin Mini

connector

Port 2

(outlet)

Port 1

(inlet)

5-pin M12

connector

Port X-1

(1/8 external

pilot supply)

Solenoid Pilot Controlled Models (CNOMO Style)

Model Numbers*

Port Size

C

v

Dimensions

inches (mm)

Weight

1, 2

1 - 2

A

B

C

lb (kg)

SV27NC115408CSAA1A**

1/2

4.5

5.0 (127)

8.5 (215)

3.3 (84)

5.0 (2.3)

SV27NC115508CSAA1A**

3/4

8.3

5.0 (127)

8.5 (215)

3.3 (84)

5.0 (2.3)

SV27NC115608CSAA1A**

1

10.3

5.0 (127)

8.5 (215)

3.3 (84)

5.0 (2.3)

Pressure Controlled Models

SV27NC115405ASAA

1/2

4.5

5.0 (127)

6.1 (154)

3.3 (84)

4.0 (1.8)

SV27NC115505ASAA

3/4

8.3

5.0 (127)

6.1 (154)

3.3 (84)

4.0 (1.8)

SV27NC115605ASAA

1

10.3

5.0 (127)

6.1 (154)

3.3 (84)

4.0 (1.8)

*NPT port threads. For BSPP threads, replace “N” in the model number with a “D”, e.g. SV27DC115408CSAA1A.
** “1A”=120 volts 60 Hz solenoids. For 24 volts DC change “1A” to “1D”.

Solenoid Pilot Controlled Models ( Pacer Style)

Model Numbers*

Port Size

C

v

Dimensions

inches (mm)

Weight

1, 2

1 - 2

A

B

C

lb (kg)

SV27NC117608CSAA1A**

1

20

5.7 (145)

11.8 (299)

3.8 (99)

12.5 (5.6)

SV27NC117708CSAA1A**

1

¼

29

5.7 (145)

11.8 (299)

3.8 (99)

12.5 (5.6)

SV27NC117808CSAA1A**

1

½

33

5.7 (145)

11.8 (299)

3.8 (99)

12.5 (5.6)

Pressure Controlled Models

SV27NC117605ASAA

1

20

5.7 (145)

8.6 (218)

3.8 (99)

11.0 (5.0)

SV27NC117705ASAA

1

¼

29

5.7 (145)

8.6 (218)

3.8 (99)

11.0 (5.0)

SV27NC117805ASAA

1

½

33

5.7 (145)

8.6 (218)

3.8 (99)

11.0 (5.0)

*NPT port threads. For BSPP threads, replace “N” in the model number with a “D”, e.g. SV27DC117608CSAA1A.
** “1A”=120 volts 60 Hz solenoids. For 24 volts DC change “1A” to “1D”.

2X O 0.26 (6.7)

C

B

A

Port PV

(pressure

verification)

1/4 Signal port

1/4 Signal port

5-pin M12

connector

Port 2

(outlet)

Port 1

(inlet)

2X O 0.53 (13.5)

C

B

A

Port PV

(pressure

verification)

1/4 Signal port

1/4 Signal port

5-pin M12

connector

Port 1

(inlet)

Port 2

(outlet)

Pressure Controlled Model

Solenoid Pilot Controlled Model (Pacer Style)

Pressure Controlled Model

Solenoid Pilot Controlled Model (CNOMO Style)