airVantage Servicing - Power Generation module

To service the power generation module, first shut off and

bleed the air being supplied to the pump. For safety purposes

the air supply line should be disconnected from the pump.

Then shut off the suction and discharge lines to the pump.

Bleed the pressure from the pump suction and discharge lines

and remove the lines from the pump. During the servicing of

the AirVantage, consult the “AirVantage Composite Repair

Parts Drawing”.

Step #1: Remove the Patch Cable

Twist the ribbed portion of the patch cable connector in

a counterclockwise direction, until it unthreads from the

connector. The cable can either be removed from the

intermediate or from the control module.

Step #2: Remove the AirVantage from the Pump

Use a ½” socket and remove the four 5/16-18 x 5 1/2 cap

screws that hold the AirVantage to the pump. Remove the two

bolts that are holding the right side bracket to be able to remove

the right bracket and AirVantage unit from the pump. Be sure

to support the weight of the AirVantage while removing the last

cap screw. After the AirVantage is removed from the pump, set

the unit down on the plastic cover located on the bottom.

Step #3: Access the Power Generation Module

Use a 5/32 hex-key wrench and loosen the four 10-32 x .50

socket head cap screws securing the bottom cover. Lift the

bottom cover off, exposing the power generation module.

There is a molded o-ring seal located on the underside of the

cap. Make sure the o-ring stays located within the groove.

If the power generation module needs to be replaced, unplug

the connector that connects the power generator to the control

board. Use a 5/32 hex-key wrench to loosen the four 10-32 x

2 ¼ socket head cap screws. The power generation module

should now be loose. Carefully lift the power generation

module off the rest of the assembly, making sure that the

control board wire and connector slips through the hole in the

power generation case.

"AirVantage Caution" - Take caution not to loosen the

o-ring that seals between the components.

Step #4: Reinstallation

When reinstalling the new module make sure to feed the

control module wire through the hole in the power generation

case. Install the four 10-32 x 2 ¼ socket head cap screws and

tighten to 60 in-lbs.

“AirVantage Caution” – Be sure to reattach the connector

from the power generator to the control board.

Reinstall the bottom cover, making sure the o-ring seal is still

in the groove. Tighten the four 10-32 x .50 socket head cap

screws to 30 in-lbs.

Reinstall the top cover, making sure the o-ring seal is still in the

groove. Tighten the four 10-32 screws. Reinstall the AirVantage

right bracket, chamber bolts/nuts and four 5/16-18 x 5 1/2 cap

screws, torque to 90 in-lbs.

“AirVantage Caution” – Be sure to reattach the patch cable

connector that connects the AirVantage module to the

intermediate.

Note: Refer to Composite Repair Parts

List on page 18 for part numbers