beautypg.com

Reelcraft Safe-T-Reel Power Cable Reels (T-15xx-x) User Manual

Operating instructions, Safe-t-reel power cable reels, Important

background image

Operating Instructions

Reelcraft Industries, Inc. • 2842 E Business Hwy 30, Columbia City, IN 46725

Ph: 800-444-3134 / 260-248-8188 • Fax: 800-444-4587 / 260-248-2605

Customer Service: 855-634-9109 • [email protected] • www.reelcraft.com

Safe-T-Reel Power Cable Reels

Model Numbers:

T-1535-003

T-1535-083-100

T-1535-103-200

T-1535-123-100

T-1535-123-200

Read this manual carefully before installing, operating or

servicing this equipment.

IMPORTANT

Four 1/2” diameter mounting holes

Dimensions

A

B

C

D

E

19”

18”

6”

6 1/2”

15 3/4”

Form# 1106-801 Rev: 3/2014

A

B

E

C

D

• Before connecting reel to supply line ensure that voltage/amper-

age does not exceed maximum rated working voltage/amperage
rating of reel.

• Ensure that reel is properly installed before connecting to supply

line (see installation instructions).

• Do not wear loose fitting clothing while operating reel.
• Be aware of other personnel in work area.
• Treat and respect the reel as any other piece of machinery,

observing all common safety practices.

SAFETY

Personal injury and/or equipment damage may result if proper safety precautions are not observed.

INSTALLATION INSTRUCTIONS

Inspection
Unpack and inspect reel for damage. Turn the reel by hand to check
for smooth operation. Check for completeness.

Mounting of the hose reel
Note: Ensure that only a qualified electrician installs / services this
equipment.
1. Four 1/2” diameter mounting holes are located at the base

of the reel. Mount reel using four (customer supplied) bolts;
tightening them securely to ensure a solid, rigid attachment
(figure 1 on page 2).

Electrical
Note: Observe any applicable NEC, OSHA and local electrical codes
when installing this equipment.

1. Remove spool cover by loosening the six self-tapping screws

that hold it in place (figure 2 on page 2).

2. Feed output cable through hole located within the spool. Pull

enough cable through for roughly half an inner wrap.

3. Remove 6” of output cable outer jacket and add fork terminals

to ends. Locate terminal block assemblies behind cover.

4. Connect black output cable to terminal block assembly

(figure 3 on page 2).

5. Connect green output cable to terminal block assembly

(figure 3 on page 2).

6. Connect white ouput cable to terminal block assembly

(figure 3 on page 2).

7. Use an Ohmmeter to check for ground defaults.
8. Replace cover and secure cord onto cord clip.
9. Wind cord onto reel.