Reelcraft Safe-T-Reel Power Cable Reels (T-15xx-x) User Manual
Operating instructions, Safe-t-reel power cable reels, Important
Operating Instructions
Reelcraft Industries, Inc. • 2842 E Business Hwy 30, Columbia City, IN 46725
Ph: 800-444-3134 / 260-248-8188 • Fax: 800-444-4587 / 260-248-2605
Customer Service: 855-634-9109 • [email protected] • www.reelcraft.com
Safe-T-Reel Power Cable Reels
Model Numbers:
T-1535-003
T-1535-083-100
T-1535-103-200
T-1535-123-100
T-1535-123-200
Read this manual carefully before installing, operating or
servicing this equipment.
IMPORTANT
Four 1/2” diameter mounting holes
Dimensions
A
B
C
D
E
19”
18”
6”
6 1/2”
15 3/4”
Form# 1106-801 Rev: 3/2014
A
B
E
C
D
• Before connecting reel to supply line ensure that voltage/amper-
age does not exceed maximum rated working voltage/amperage
rating of reel.
• Ensure that reel is properly installed before connecting to supply
line (see installation instructions).
• Do not wear loose fitting clothing while operating reel.
• Be aware of other personnel in work area.
• Treat and respect the reel as any other piece of machinery,
observing all common safety practices.
SAFETY
Personal injury and/or equipment damage may result if proper safety precautions are not observed.
INSTALLATION INSTRUCTIONS
Inspection
Unpack and inspect reel for damage. Turn the reel by hand to check
for smooth operation. Check for completeness.
Mounting of the hose reel
Note: Ensure that only a qualified electrician installs / services this
equipment.
1. Four 1/2” diameter mounting holes are located at the base
of the reel. Mount reel using four (customer supplied) bolts;
tightening them securely to ensure a solid, rigid attachment
(figure 1 on page 2).
Electrical
Note: Observe any applicable NEC, OSHA and local electrical codes
when installing this equipment.
1. Remove spool cover by loosening the six self-tapping screws
that hold it in place (figure 2 on page 2).
2. Feed output cable through hole located within the spool. Pull
enough cable through for roughly half an inner wrap.
3. Remove 6” of output cable outer jacket and add fork terminals
to ends. Locate terminal block assemblies behind cover.
4. Connect black output cable to terminal block assembly
(figure 3 on page 2).
5. Connect green output cable to terminal block assembly
(figure 3 on page 2).
6. Connect white ouput cable to terminal block assembly
(figure 3 on page 2).
7. Use an Ohmmeter to check for ground defaults.
8. Replace cover and secure cord onto cord clip.
9. Wind cord onto reel.