beautypg.com

Installing the input hose mounting the hose reel, Mounting applications – Reelcraft Series RT Spring Driven Hose Reels (Medium and High Pressure) User Manual

Page 2

background image

Series RT Spring Driven Hose Reels

Page 2

www.reelcraft.com

Installing the Input Hose

Mounting the Hose Reel

Prior to mounting the hose reel, ensure that the supply line pressure does

not exceed the maximum working pressure of the hose reel.
Do not exceed the maximum installation height of 16’ unless the reel was

specified differently when ordering. The maximum operating temperature

is 150°F (66°C).
Unpack and inspect the reel for damage. Turn the spool by hand to check

for a smooth operation.
Position the reel on the floor, wall or ceiling. Secure into place using four

mounting bolts (not included). See the included mounting template for

additional instructions for your specific mounting application. Depending

on where the reel is placed, it may be necessary to adjust the hose bumper

and guide arm to use the hose properly. See the instructions on the next

page to adjust the hose bumper and reposition the guide arm.

Use a flexible hose connection at input. Do not use rigid

plumbing. (input hose not included)
Apply pipe thread sealant to threads on standard reels.
Do not over tighten the connection. Recommended torque

should not exceed 70 ft./lb.

Mounting Applications

figure 1

figure 2

figure 3

figure 4

figure 5