Programming procedure, Continued) – Rapid-Air SERVO FEED / RAPID MASTER User Manual
Page 10
0
programming procedure
(continued)
Operator.Input.Terminal.–.Programming.Procedure.–.Standard.Software
. MANUAL.MODE.F1=INCH
. F2=SINGLE.FEED.MODE
. F4=EXIT.MANUAL.MODE
. CYCLE.ROLL.WITH.KEYS
.
F2=SINGLE.FEED
If the operator presses F2 then the
following screen is displayed. The
single feed mode is active and every
time the F1 key is pressed then the
feed will cycle and move the distance
indicated on the feed length line.
JOB#=00.......FL=000.000
. F1=FEED.SINGLE.LNGTH
. F2=CUT.F3=SINGLE.CYC
. F4=EXIT.(SINGLE.FEED)
Pressing F4 once resets the program
to the manual mode display. Pressing
the F4 key twice resets the program
to the main menu display. If the F4
key was pressed twice the following
screen is displayed.
. MAIN.SELECTION.MENU
. F1=JOB#..F2=MANUAL
. F3=AUTOMATIC.CYCLE
. F4=REVIEW.JOB.PROGRAM
F3=AUTOMATIC.CYCLE
You can now select between batch or
continuous mode
. SELECT.CONTINUOUS.OR
. BATCH.CYCLE.F1=BATCH
. F2=CONTINUOUS.CYCLE
. F4=EXIT.TO.MAIN.MENU
F2=CONTINUOUS
If the F2 key was pressed then the
servo will be in the auto total mode
and the following screen appears.
. AUTOMATIC.TOT=000000
. JOB#=00.CUT=O.150
. FL=000.000.SPEED=100
. ACCEL=OO1%.F4=RETURN
Pressing the F4 key, stops the
automatic cycle and the main menu
screen appears.
. MAIN.SELECTION.MENU
. F1=JOB#..F2=MANUAL
. F3=AUTOMATIC.CYCLE
. F4=REVIEW.JOB.PROGRAM
F3=AUTOMATIC.CYCLE
If the feed has been properly set up,
tested in manual, press electrically
interlocked with feed, feed and pilot
switches wired to the correct
terminals, then pressing the F3 key
will display the following screen.
. SELECT.CONTINUOUS.OR
. BATCH.CYCLE.F1=BATCH
. F2=CONTINUOUS.CYCLE
. F4=EXIT.TO.MAIN.MENU
F1.=BATCH
If the F1 key was pressed then the
servo will be in the auto batch mode
and the following screen appears.
. BATCH.SETTING=000000
. BATCH.COUNTER=000000
. F1=RESET.BATCH.COUNT
. F4=CONTINUE.WITH.COUNT
If F1 (reset batch count) is pressed
then the batch count will be reset
to its preset valve. If F4 (continue
with count) is pressed the batch
count will remain at its present
value. Either F1 or F4 will lead to the
following screen.
. AUTOMATIC.BATCH=000000
. JOB#=XX..CUT=0.XXX
. FL=XXX.XXX..SPEED=XXX%
. ACCEL=XXX%..F4=RETURN
Pressing the F4 key, stops the
automatic cycle and the main menu
screen appears.
When the automatic screen is
displayed, all keys except the F4 key
are inactive. Every time the press
cycles and trips the feed switch,
the feed will cycle once per the
parameters displayed on the screen.
If the feed encounters excessive
material drag while feeding or the
material being moved encounters
a restriction that stops the material
forward movement then a servo fault
can occur. If this happens then the
following screen is displayed.
. DRIVE.FAULT.OCCURED
. NOTE.TYPE.OF.FAULT––
. (xxx)
Example of fault – (2) = motor over
temperature.
Look.up.fault.code.printout.listed.in.
this.manual.
To reset the fault, the master on-off
switch has to be cycled which will
reset the controller. The material path
should be checked for obstruction and
parallelism to the die. If all this seems
to be satisfactory and another fault oc-
curs the factory should be consulted.
. MAIN.SELECTION.MENU
. F1=JOB#..F2=MANUAL
. F3=AUTOMATIC.CYCLE
. F4=REVIEW.JOB.PROGRAM