beautypg.com

Troubleshooting, Caution – Lincoln Electric IM10020 TOMAHAWK 625 User Manual

Page 25

background image

1. This may be normal. If output is

set to maximum a 30 amp circuit
is required. See Technical
Specification page.

2. Install a larger input circuit or turn

the output control to a lower
amperage.

1. Check the input power to be sure

it is on.

2. Check the power line fuses or

breakers and machine connection.

3.

Disconnect input power at
fuse/breaker panel and check line
switch continuity. Replace line
switch if bad.

1. Possible faulty Inverter Board.

2. Possible faulty Control Board.

1. Check consumables - Thermal

and output LEDʼs light when an
unsafe condition exists at the
torch.

2. Possible faulty Inverter Board.

3. Possible faulty Control Board.

E-3

TROUBLESHOOTING

E-3

TOMAHAWK™ 625

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Input circuit breaker trips repeatedly.

No Status indicators light and the fan
does not operate 5 seconds after the
power switch is turned on.

No Status indicators light 5 seconds
after the power switch is turned on,
but the fan operates.

The Thermal LED does not go out.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.