beautypg.com

Troubleshooting – Lincoln Electric IM10020 TOMAHAWK 625 User Manual

Page 24

background image

E-2

TROUBLESHOOTING

E-2

TOMAHAWK™ 625

ERROR SIGNALS

Alarm

(abnormal condition)

Undervoltage

Overvoltage signal

Underpressure

PIP (Parts In Place)

Thermal Shutdown

OCV

Overvoltage shutdown

RED

LED

OFF

Blink

Blink

ON

OFF

Blink

OFF

YELLOW

LED

Blink

OFF

OFF

ON

ON

Blink

Blink

Blinking fre-

quency (Hz)

1

4

1

steady on

steady on

1

3

Reset mode

Autoreset with hysteresis.

Autoreset with hysteresis.

Autoreset.

Autoreset after 5sec.

Autoreset after cooling time.

Autoreset after trigger release.

Autoreset after 2min of cooling

time.

NOTE

Error and shutdown when the input voltage is less than

187Vac.

Error when the input voltage is greater than 270Vac.

Error and shutdown when the input air pressure is low.

Error and shutdown when the retaining cap is not

attached properly.

Normal thermal response due to overheating.

Safe Mode - if trigger is pulled while turning the machine

on, or attaching consumables with the trigger pulled.

This shutdown occurs if the machine cuts for more than

20sec in overvoltage condition (Vin>270Vac).

Signal

(normal operation)

Power on

Inverter on

GREEN

LED

ON

ON

RED

LED

OFF

ON

Blinking fre-

quency (Hz)

steady on

steady on

Reset mode

Always on when the machine is

energized.

When the torch trigger is released.

NOTE

Normal operating condition when trigger is off.

Normal operating condition when trigger is pulled.