Setting up to mark (overrides cut), Verifying input gas pressures – Lincoln Electric 718118 Spirit II 400 User Manual
Page 47

Spirit II User’s Manual
Section 4: Operation with Manual Gas Console
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
4-3
Setting up to Mark (Overrides Cut)
The system will automatically switch between cutting and marking based upon
commands in the part program. However, all cutting commands in the part program can
be overridden with marking commands by simply changing the
Process to Marking.
Push the
OFF Button on the MGC to disable
the system. On the main menu, move the
pointer to
Setup. Press SELECT.
Press SELECT to cycle through the list until
Marking is displayed. Move the pointer to
Return and press SELECT.
The system is now setup to mark instead of
cut.
Verifying Input Gas Pressures
For the system to work properly the input gas pressures must be within an acceptable
range. To check the input pressures, follow the steps below.
On the main menu, move the pointer to
Input Gas. Press SELECT.
Verify that all connected gas pressures are at
least 120psi. The maximum input gas pressure
is 145psi.
Press SELECT to return to the main menu.