Setting up to cut – Lincoln Electric 718118 Spirit II 400 User Manual
Page 46

Section 4: Operation with Manual Gas Console
Spirit II User’s Manual
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
4-2
Setting up to Cut
The following procedure uses the information from the cutting charts in Section 5 to
prepare the system to cut. Press the UP or DOWN button on the MGC to move the
pointer through the menu as described below.
Push the
OFF Button on the MGC to disable
the system. On the main menu, move the
pointer to
Setup. Press SELECT.
Press SELECT to cycle through the list until
Cutting is displayed.
Move the pointer to
Current.
Press SELECT to cycle through the list until
the desired amperage is displayed.
Move the pointer to
Select Gas.
Press SELECT.
Press SELECT to choose the
Plasma gas.
Move the pointer to
Shield and press SELECT
to choose the shield gas. Move the pointer to
Return and press SELECT.
Move the pointer to
Adjust Gas.
Press SELECT.
Move the pointer to a gas and then press
SELECT to start the flow of that gas. Turn the
corresponding regulator knob on the MGC to
adjust the displayed pressure to match the
value in the cutting chart. Repeat for all other
gases. Move the pointer to
Return and press
SELECT. Repeat to return to the main menu.
The system is now setup to cut.