Installation, Technical specifications - power wave, R500 – Lincoln Electric IM10133 POWER WAVE R500 User Manual
Page 7
A-1
INSTALLATION
POWER WAVE
®
R500
A-1
TECHNICAL SPECIFICATIONS - POWER WAVE
®
R500
RECOMMENDED INPUT WIRE AND FUSE SIZES
1
INPUT
VOLTAGE / PHASE/
FREQUENCY
200-208/3/50/60
230/3/50/60
380-415/3/50/60
460/3/50/60
575/3/50/60
TIME DELAY FUSE
OR BREAKER
2
AMPERAGE
100
90
60
45
35
CORD SIZE
3
AWG SIZES
(mm
2
)
4 (21)
4 (21)
8 (10)
8 (10)
10 (7)
MAXIMUM INPUT
AMPERE RATING AND
DUTY CYCLE
80A, 40%
73A, 40%
41A, 40%
37A, 40%
29A, 40%
RATED OUTPUT
POWER SOURCE-INPUT VOLTAGE AND CURRENT
Model
K3169-1
Duty Cycle
40% rating
100% rating
450 Amps
36.5 Volts
550 Amps
41.5 Volts
500 Amps
39 Volts
INPUT
VOLTAGE/PHASE/
FREQUENCY
200-208/3/50/60
230/3/50/60
380-415/3/50/60
460/3/50/60
575/3/50/60
Input Amperes
80/73/41/37/29
60/54/30/27/21
Idle Power
500 Watts Max.
(fan on)
Power Factor @
Rated Output
.95
Input Voltage ± 10%
208/230/400*460/575
50/60 Hz
(includes 380V to 415V)
1. Based on U.S. National electrical Code
2. Also called " inverse time" or "thermal / magnetic" circuit breakers; circuit breakers that have a delay in trip-
ping action that decreases as the magnitude of the current increases
3. Type SO cord or similar in 30° C ambient at effective current rating of unit.
GMAW
40%
60%
100%
SMAW
GTAW-DC
450 Amps
38 Volts
550 Amps
42 Volts
500 Amps
40 Volts
40%
60%
100%
450 Amps
28 Volts
550 Amps
32 Volts
500 Amps
30 Volts
40%
60%
100%