beautypg.com

Installation, Warning – Lincoln Electric IM10104 MAGNUM K3092-,K3093-,K3098-, K3130- PRO CURVE User Manual

Page 11

background image

B-1

INSTALLATION

B-1

Read this entire installation section before you
start installation.

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts

such as output terminals or inter-
nal wiring.

• Insulate yourself from the work and

ground.

• Always wear dry insulating gloves.

------------------------------------------------------------------------

Only qualified personnel should install, use or
service this equipment.

CONNECTOR KIT INSTALLATION TO GUN
CABLE

The K3092, K3093, K3098 and K3130 MAGNUM

®

PRO

CURVE DP and DS procedure cables are shipped as
generic assemblies and must be assembled with a con-
nector kit.

The K3092, K3093, K3098 and K3130 MAGNUM

®

PRO CURVE DP and DS guns and cable are
equipped with a control cable that attaches to a
Lincoln -10 series wire feeder. For other wire feeders
the control cable has to be rewired with the appropri-
ate connectors to fit the wire feeder.

K466-1& -8 INSTALLATION (For Lincoln Feeders)

a. Remove brass cable connector and insulation tube

(see Figure B.1) from the K466-1 kit. Slide the
insulation tube onto the connector from the thread-
ed end and screw it onto the feeder end of the gun
cable. Tighten the connection with the wrench pro-
vided.

b. Remove the molded gas plug fitting on the side of

the feeder end handle and replace it with the
barbed brass fitting provided in the kit. The includ-
ed wrench will fit both the gas plug and barbed fit-
ting.

c. Attach the round connector of the gun control cable

provided to the trigger connector on the front of the
Lincoln feeder. (NOTE: Both the plug and socket
are keyed and must be properly oriented.)

d. Place one tubing clamp onto each end of the flexi-

ble tubing provided, approximately 2” (51 mm) in
from each end. Slide one end of the tubing onto the
barbed connector on the feeder end cable handle
(step b) and move the clamp down near the end of
the tube to ensure a good gas seal.

MAGNUM

®

PRO CURVE DUAL PROCEDURE & DUAL SCHEDULE

WARNING

NOTE: An optional K481 MAGNUM® Fast-Connect
Gas Tube Kit is available to provide tool-less gas tube
connection to Lincoln wire feeders. Install per the
instructions sent with the kit.

K466-2 INSTALLATION (For Tweco Adapted
Feeders)

a. Remove brass cable connector (see Figure B.1)

from the K466-2 kit and screw it onto the feeder
end of the gun cable. Tighten the connection with
the wrench provided.

b. Check that the molded gas plug fitting is sealing

the gas fitting hole in the side of the feeder end
handle.

K466-3 INSTALLATION (For Miller Feeders)
NOTE: K3159-1 Control Cable Assembly is required.

a. Remove brass cable connector (see Figure B.1)

from the K466-3 kit and screw it onto the feeder
end of the gun cable. Tighten the connection with
the wrench provided.

b. Check that the molded gas plug fitting is sealing

the gas fitting hole in the side of the feeder end
handle.

c. Attach the round connector of the K3159-1 gun

control cable to the trigger connector on the front of
the Miller feeder.