A-1

INSTALLATION

IDEALARC

®

AC-1200

A-1

Weight

1636 lbs.

(742 kg.)

INPUT - SINGLE PHASE ONLY

RATED OUTPUT

PHYSICAL DIMENSIONS

RECOMMENDED INPUT WIRE GROUNDING CONDUCTOR AND FUSE SIZES

Standard Voltage

Duty Cycle

100%

Current Range

240/1200

Maximum Open Circuit Voltage

Depth

38.00 in.

(965.2mm.)

Width

22.30 in.

(566.4mm.)

Height

53.50 in.

( 1358.9mm.)

AMPS AC

1200 @ 44 Volts

Input Current at 100% Rated Output

Single Phase Output

Scott Connection

460/60

440/50/60
415/50/60
380/50/60

182

209

190

219

201

232

220

255

TECHNICAL SPECIFICATIONS - IDEALARC

®

AC-1200

86-88

RATING: IP21 ENCLOSURE

Power Factor @ Rated load With P.F. Capacitors

79%(60 Hz)

76%(50 Hz)

Input Copper Wire Size - 75˚C in Conduit Super Lag Fuses

Voltage/ Input Amps Power Input Wires Grounding Conductor Size in Amps

Hertz

1 Phase Scott

1 Phase

Scott

1 Phase

Scott

1 Phase Scott

Conn.

Conn.

Conn.

Conn.

460/60

182

209

#4/0

250MCM

#4

#3

300

350

440/50/60

190

219

#4/0

250MCM

#4

#3

300

350

415/50/60

201

232

#4/0

300MCM

#4

#3

300

350

380/50/60

220

255

250MCM

350MCM

#3

#3

300

400