beautypg.com

Diagrams, Ac-1200 scott connection diagram, Idealarc – Lincoln Electric IM10119 IDEALARC AC-1200 User Manual

Page 20: Ac-1200

background image

F-3

DIAGRAMS

F-3

IDEALARC

®

AC-1200

M10033-1

A.01

100

90

80

L2

L1

L2

L1

P1

C

B

A

TO GROUND PER NATIONAL
ELECTRIC CODE.

WORK

ELECTRODE

WORK

ELECTRODE

N.B.

MAIN TRANSFORMER
LEAD ARC

4/O CABLES

4/O CABLE

N.C.

TEASER TRANSFORMER
TRAIL ARC

4/O CABLES

4/O CABLE

N.C.

100

90

80

L2

L1

L2

L1

P1

C

B

A

TO GROUND PER NATIONAL
ELECTRIC CODE.

WORK

ELECTRODE

WORK

ELECTRODE

N.B.

N.B.

N.B.

3 PHASE SUPPLY LINE (N.A.)

NOTES:

N.B.

ELECTRODE CABLES OF PARALLELED MACHINES SHOULD BE CONNECTED TO THE SAME RANGE TAP.

N.C.

NUMBER OF 4/O CABLES CONNECTED: 1 ON MIN. TAP; 2 PARALLEL ON MED. TAP; 3 PARALLEL ON MAX. TAP.

TWO PARALLEL MACHINES SCOTT CONNECTED TO TWO OTHER PARALLEL MACHINES

FOR DESIRED PHASE ANGLE, INTERCONNECT MACHINES (AS SHOWN BELOW).
BOTH PHASE ANGLES MUST BE THE SAME.

N.A.

TO OBTAIN NORMAL PHASE SEQUENCE AT THE WELDING ARCS, THE INPUT LINE PHASE SEQUENCE SHOULD BE A-C-B.

AC-1200 SCOTT CONNECTION DIAGRAM