Warner Electric CBC-1550AHFC User Manual
Page 9

9
Warner Electric • 800-825-9050
819-9050
Programming
Line Display
Description
Options
Default
Program
1
h.
Home Reference Number
— — — —
0
2
bd.
Initial Braking Distance
— — — —
25
3
bd.AuE.
# of Cycles Averaged
1 - 9
3
4
cc.
Correction Constant
— — — — ––
0.5000
5
dP.
Decimal Point
off, .0, .00, .000
oFF
6
FrSt.
Front Panel Reset
on - off
on
7
PLoc.
Front Panel Lock
on - off
oFF
8
CrEt.
Count Retention
on - off
oFF
9
ArSt.
AUTO Reset
on - off
on
10
ol.
Start Output
00.00 to 99.99
00.20
11
o2.
Early Warning Output
00.00 to 99.99
00.01
12
o3.
Brake on Output
00.00 to 99.99
00.20
13
o4.
Zero Speed Output
00.00 to 99.99
00.10
14
o5.
Zero Speed + Delay 1
00.00 to 99.99
00.05
15
o6.
Zero Speed + Delay 2
00.00 to 99.99
00.05
16
o8.
Batch Counter Reset
00.00 to 99.99
LATCH
17
dl.
Delay Time 1
00.00 to 99.99
00.10
18
d2.
Delay Time 2
00.00 to 99.99
00.01
19
05P.
Zero Speed Window
.01, .05, .10, .25 sec.
.25
20
5
Start Command Release
Outputs .no change
__ __ __ __ __ __
1-6
d .drop out
. . . . .
21
L
Move Preset Release
Outputs . no change
__ __ __ __ __ __
1-6
d .drop out
. . . . .
22
E
Early Warning Release
Outputs . no change
__ __ __ __ __ __
1-6
d .drop out
. . . . .
23
r
Reset Command Release
Outputs . no change
__ __ __ __ __ __
1-6
d .drop out
. . . . .
24
br.
Baud rate
off, 300, 600, 900
oFF
1200, 2400
25
PAr
Parity
nonE, odd, EuEn
nonE
26
id.no.
Identification Number
0 - 99
0
27
t0.
Keyboard Test
rdy
y
28
tl.
Non-Volatile RAM Test
Press
y
29
t2
Input Test
Ab - encoder inputs
1 - start
2 - stop
y
3 - cont. 4 reset
30
t3
Output Test
1 - E
y
31
t4
Display Test
Press
y
32
t5
Program Memory Test
Press
y
33
t6
Date Code Test
Press
y
34
t7
Serial Test
Press
y
35
t8
Factory Default Settings
Press
y
Refer to
Diagnostics
Test Page 9