beautypg.com

Master, slave mode device testing, Timing master device, Timing slave device – Teledyne LeCroy QPHY-MOST50 User Manual

Page 21: Qphy-most50e software option

background image

QPHY-MOST50e Software Option

920457 Rev B

21

Master, Slave Mode Device Testing

Timing Master Device

A Timing Master device is responsible for supplying a MOST network with MOST frames and
therefore can be operated without the use of any external generator. It is capable of generating the
signals required for compliance testing.

Timing Slave Device

In a MOST network a Timing Slave device synchronizes itself to MOST frames generated by the Timing
Master device and regenerates the frames at the same network rate. For compliance testing an external
signal generator is used to provide the necessary frames by simulating an ideal Timing Master device.