beautypg.com

11 ipegenoptions2::setskew, Parameters, Return values – Teledyne LeCroy Automation API for Teledyne LeCroy PETracer_PETrainer User Manual

Page 104: Remarks, Example, Ipegenoptions2::setskew

background image

Teledyne LeCroy

Automation API for PETracer/PETrainer

99

6.3.11 IPEGenOptions2::SetSkew


HRESULT SetSkew (

[in] int lane,
[in] int skew )


Allows skew values to be set for each lane of outgoing traffic.

Parameters

lane

Specifies the lane to set the skew value on

skew

Specifies the numeric value for the skew on the specified lane; allowed

values are from 0 to 7


Return values


Remarks

Example


WSH:

Set Analyzer = WScript.CreateObject( “CATC.PETracer” )
Set GenOptions = Analyzer.GetGenerationOptions

GenOptions.SetSkew( 0, 0 )

‘ set skew value 0 for lane 0

GenOptions.SetSkew( 1, 2 )

‘ set skew value 2 for lane 1

GenOptions.SetSkew( 2, 0 )

‘ set skew value 0 for lane 2

GenOptions.SetSkew( 3, 3 )

‘ set skew value 3 for lane 3

C++: