5.1.2 IRecOptions::Save


HRESULT Save (

[in] BSTR ro_file_name );


Saves recording options into the specified file.

Parameters


ro_file_name

String that provides the full pathname to the recording options file

Return values

ANALYZERCOMERROR_UNABLEOPENFILE –

unable to open file

Remarks

If the specified file does not exist, it will be created. If it exists, it will be overwritten.

Example


WSH:

CurrentDir = Left(WScript.ScriptFullName, InstrRev(WScript.ScriptFullName, "\"))
Set Analyzer = WScript.CreateObject("LeCroy.FCAnalyzer")
Set RecOptions = Analyzer.GetRecordingOptions
' do the changes of recording options here
RecOptions.Save( CurrentDir & "Input\rec_options.rec" )

C++: