Planning the installation (continued…) 4, Installing the system chassis into the rack 5, Introduction 1 – Teledyne LeCroy 1U Height Systems Rack Mount User Manual
Page 4: Rack mount kit components 2

WARNING: In order to provide stability to the rack, systems should 
first be installed from the bottom with the heaviest components
Planning the Installation (continued…)
4
A location for the system chassis should be planned taking these restrictions into 
consideration.
first be installed from the bottom, with the heaviest components 
located in the bottom of the rack. If the rack is provided with 
stabilizing devices, install the stabilizers before mounting or 
servicing the unit in the rack.
S
i
d Ai fl
Spacing and Airflow
Allow, at a minimum, 1“ of air space around each side of the system, and 3-4” of 
space in the rear of the system. This allows adequate airflow to cool the system. 
The air temperature within the rack enclosure should not exceed 122°F (50°C).
Power Supply
The system requires a source of AC power (100-240V, 50-60 Hz, 230W) routed to
Installing the System Chassis into the Rack
5
Follow these steps to install the system chassis in an open rack that enables you
y
q
p
(
,
,
)
the rear of the system. All other controls and wiring connections are located on the 
front panel of the system.
p
y
p
y
to slide the chassis in from the front.
Step 1:
Position the chassis in the rack as follows:
Step 2:
Use your tape measure and level to ensure that the supporting shelf and 
the chassis are installed straight and level.
Step 3:
Make sure that your path to the rack is unobstructed
Step 3:
Make sure that your path to the rack is unobstructed.
Step 4:
Slide the unit into the rack and position using the attached L brackets so 
that the slots in the brackets are positioned over the appropriate 
mounting holes in the side rails of the rack.
Step 5:
Securely fasten the unit into the rack by using the four 10-32 x 0.5 
screws which are supplied with the rack mount kit, installing two of the 
screws on each side of the unit Use a Phillips screwdriver to tighten the
screws on each side of the unit. Use a Phillips screwdriver to tighten the 
screws.
This concludes the rack mount installation.
PN: 920060-00 Rev B
v0812
Rack Mount Installation Guide
Sierra 1U Height Systems
This manual describes the procedure to retrofit Sierra
1U-sized systems for rack mounting at your site. The 
rack mount kit is for securing these systems in an 
EIA 310-D 19-inch equipment rack. The rack mount kit 
Introduction
1
is included with some systems, or may be purchased 
as an accessory for existing systems.
Two brackets, which are attached (as shown in this 
document) to the side of the chassis, connect the 
chassis to the mounting posts of the rack. 
Some racks provide a power strip along the length 
of one of the rear posts. If your rack has this feature, 
the systems and the rack mounting brackets are 
designed so that power can be supplied to the rear of the unit while network cables 
and user control is available at the front (exposed) portion of the system.
Rack Mount Kits covered by this document include kits for the Sierra™ M124, 
SierraNet™ M408 and SierraFC™ M164.
The kit includes the following components:
Quantity
Part Description
Rack Mount Kit Components
2
2
Rack Mount Brackets
1
9/64” Allen Key
4
10-32 x 0.5 Screws 
(for securing the 
system chassis to the
You will also need the following 
additional tools:
•
Tape Measure
•
Level
•
Phillips Screwdriver
system chassis to the 
rack)
4 x Screws
2 Rack Mount Brackets
1 x Allen Key
•
Phillips Screwdriver
y