Installation Instructions
All products covered by this instruction sheet are war-
ranted against defects in workmanship and materials for
one year from date of installation, except heating ele-
ments which are warranted against defects in workman-
ship and materials for five years from date of installation.
This warranty does not apply to damage from accident,
misuse, or alteration; nor where the connected voltage
is more than 5% above the nameplate voltage; nor to
equipment improperly installed, wired or maintained
in violation of this instruction sheet. All claims for war-
ranty work must be accompanied by proof of the date
of installation. The customer shall be responsible for all
cost incurred in the removal or reinstallation or products,
including labor costs, and shipping costs incurred to
return products to King Manufacturing. King Mfg. will
repair or replace, at our option, at no charge to you with
return freight paid by King. King Electrical Mfg. shall
not be liable for consequential damages arising with
respect to the product, whether based upon negligence,
tort, strict liability or contract. King Manufacturing can
be contacted in Seattle, Washington by phone at (206)
762-0400, by fax at (206) 763-7738 or by email at www.
king-electric.com
Remove the heater from the box and check for any
damage. Verify that the factory installed options are
correct for the application. Remove and set aside the
grill.
Select power supply wire type and size to comply
with local and national electric codes using heater
rating given in table. Connect wire to heater as
shown in wiring diagram attached to cover. Remove
one of the knockouts from back of unit. Secure
power supply cable with clamps (or run in conduit,
if required by local codes). Also run the wiring for a
remote thermostat, if required. Connect grounding
conductor to the green screw.
Fasten the heater to the wall with #10 screws, as
shown in the mounting diagrams. On recess models,
be sure to leave enough clearance to install the grill.
Replace the grill. Test the heater for proper operation.
Warranty
WARNING
Before proceeding further with the instal-
lation of this heater, turn off the power and
lock to the supply line for the heater at the
main service box.
WARNING - All Power must be shut
off at the main service panel before
inspecting or cleaning the heater.
Maintenance
With proper care your electric heater should last a
lifetime, however seasonal cleaning is recommended
to maintain the efficiency of the heater.
To clean the heater remove the four screws that hold
the grill in place and remove the grill. Remove dust or
lint from the heating elements and the fan blades with a
soft brush, compressed air, or a vacuum cleaner. KCF
units require a few drops of SAE 20 synthetic oil on the
motor shaft. Replace the grill and tighten the screws.
JUNCTION BOX
(Left side wiring only)
KCC-KCF.indd : 4/08