DIP Switches and Jumpers

2-4

SHARC EZ-Extender Manual

When the

SW1

switch connects a direction control signal to ground (

GND

),

the corresponding signal (signals) is (are) controlled as input. The direc-
tion control functionality is summarized in

Table 2-1

.

The source of the PDAP clock input signal,

DAI_PP2_CLOCKIN

, is config-

ured through positions 1 and 2 of the DIP switch

SW1

, as illustrated in

Figure 2-1 on page 2-2

. The switch settings are summarized in

Table 2-2

.

Table 2-1. DAI_P15_GP1/DAI_P16_GP2 Direction Control Settings

SW1 Position 3
SW1 Position 5

SW1 Position 4
SW1 Position 6

DAI_P15_GP1 Direction
DAI_P16_GP2 Direction

OFF OFF

EZ-KIT Lite is transmitter

OFF ON DAI_P18

sets the direction:

0

= EZ-KIT Lite is receiver

1

= EZ-KIT Lite is transmitter

ON OFF

EZ-KIT Lite is receiver

ON ON

Do not use

Table 2-2. PDAP Clock-in Source Settings

SW1 Position 1
RX_CLK

SW1 Position 2
TX_CLK

DIA_P2_CLOCKIN Source

OFF

OFF

Not generated by the EZ-Extender

OFF

ON

In this configuration, the

TX_CLK

signal must be

generated by one of the user configured clock
sources.

ON

OFF

RX_CLK

ON

ON

RX_CLK

; in this configuration, the

RX_CLK

signal is

also routed to the

TX_CLK

to be used as an output.

This manual is related to the following products: