Table 2-2. pdap clock-in source settings – Analog Devices SHARC 82-000805-01 User Manual
Page 22
DIP Switches and Jumpers
2-4
SHARC EZ-Extender Manual
When the
SW1
switch connects a direction control signal to ground (
GND
),
the corresponding signal (signals) is (are) controlled as input. The direc-
tion control functionality is summarized in
Table 2-1
.
The source of the PDAP clock input signal,
DAI_PP2_CLOCKIN
, is config-
ured through positions 1 and 2 of the DIP switch
SW1
, as illustrated in
Figure 2-1 on page 2-2
. The switch settings are summarized in
Table 2-1. DAI_P15_GP1/DAI_P16_GP2 Direction Control Settings
SW1 Position 3
SW1 Position 5
SW1 Position 4
SW1 Position 6
DAI_P15_GP1 Direction
DAI_P16_GP2 Direction
OFF OFF
EZ-KIT Lite is transmitter
OFF ON DAI_P18
sets the direction:
0
= EZ-KIT Lite is receiver
1
= EZ-KIT Lite is transmitter
ON OFF
EZ-KIT Lite is receiver
ON ON
Do not use
Table 2-2. PDAP Clock-in Source Settings
SW1 Position 1
RX_CLK
SW1 Position 2
TX_CLK
DIA_P2_CLOCKIN Source
OFF
OFF
Not generated by the EZ-Extender
OFF
ON
In this configuration, the
TX_CLK
signal must be
generated by one of the user configured clock
sources.
ON
OFF
RX_CLK
ON
ON
RX_CLK
; in this configuration, the
RX_CLK
signal is
also routed to the
TX_CLK