beautypg.com

Remote wall thermostat, Warranty information, Troubleshooting table – King Electric Model WHF User Manual

Page 4

background image

w_install_2013.pub

King Electrical Mfg. Co. 9131 10th Ave So. Seattle, WA 98108 206-762-0400 www.king-electric.com

4

Remote Wall Thermostat

Warranty Information

King Electrical Manufacturing Company will repair or replace, without charge to the original owner, any WHF Series heater

found to be defective or malfunctioning within 1 year of installation. This warranty requires the owner or his agent install the

equipment in accordance with the National Electrical Code, any other applicable heating or electrical codes, and the manu-

facturer’s installation instructions. It further requires that reasonable and necessary maintenance be performed on the unit.

Failure to properly maintain the unit will result in the warranty being voided. The company is not liable for abuse or misuse of

product as may be finally determined by the company. The customer shall be responsible for all costs incurred in the removal

or reinstallation of products, including labor costs and shipping costs incurred to return products to King Manufacturing. King

Manufacturing will repair or replace, at our option, at no charge to the customer with return freight paid by King. King Manu-

facturing shall not be liable for consequential damages arising with respect to the product, whether based upon negligence,

tort, strict liability or contract. No other written or oral warranty applies, nor any warranties by representatives dealers, em-

ployees of King, or any other person. All returns require a King Return Goods Authorization (RGA); Unauthorized returns will

be refused. Do not return malfunctioning/defective products to store.

Figure 7

Connection Diagram for Wall Mounted Single Pole Thermostat

1. Red thermostat wire to black power supply wire.

2. Black thermostat wire to black heater wire.

3. White power supply wire to white heater wire.

4. Connect all bare ground wires together.

Connection Diagram for Wall Mounted Double Pole Thermostat

1. Connect the two red thermostat wires to the black

and white power supply wires.

2. Connect the two black thermostat wires to the black

and white heater wires.

3. Connect all the bare ground wires together.

1. Before removing grill, turn the electrical power OFF and elements to cool. Circuit breakers are often not marked

correctly and turning the wrong breaker off could mean electricity is flowing to the heater, even if the heater

does not appear to be working. If you are uncomfortable working with electrical appliances, unable to follow

these guidelines, or do not have the necessary equipment, consult a qualified electrician. Once you verify the

power is off completely and element is cool, proceed to the next step.

2. Remove screws and take off grill. Wash grille with hot soapy water and dry immediately

3. Using a hair dryer or vacuum on blow cycle, blow debris back through the element. Do not touch element.

Vacuum or use a soft brush and remove lose debris without touching the elements.

The fan motor does not re-

quire lubrication.

4. Re-attach grill and secure with screws.

5. Turn thermostat to desired setting.

6. Turn power back ON at the electrical panel board.

Maintenance & Cleaning

: Basic maintenance is listed below and should be performed annually.

When necessary, any required servicing should be performed by qualified service personnel. Your

heater will give you years of service and comfort with only minimum care. To assure efficient opera-

tion follow the simple instructions below.

Figure 6

Troubleshooting Table

WARNING: All other servicing should be per-

formed by an authorized service personnel.