beautypg.com

Ktw installation instructions, Danger, Caution – King Electric Model KTW User Manual

Page 2: Electric shock or fire hazard

background image

Figure 4.1

2

KTW INSTALLATION INSTRUCTIONS

CAUTION!

Turn OFF all electrical power

to install heater

Model and Rating Label Location

Total Amps

Minimum AWG. Wire

Size (Copper) 90 c

Circuit Breaker

or Fuse Size

1 thru 12

#14

15 amp

13 thru 16

#12

20 amp

17 thru 25

#10

30 amp

Selecting A Location For Your Heater: KT

This heater has been designed to allow it to be recessed at floor

level in the toe space of cabinets or under counters or at the base

of walls. When selecting the location, be sure the materials that

will be located in the air heated by this heater (such as floor cover-

ings) will not distort or discolor at temperatures above 140°F

(60ºC). DO NOT select a location directly beneath sinks or other

work areas where people are likely to stand for extended periods of

time. DO NOT install less than 6” (15cm) from vertical side walls or

open edge of door. This heater must have an unrestricted airflow.

DO NOT select a location where it is likely to be blocked by furni-

ture, throw rugs, etc. Be sure the location selected allows sufficient

space for the heater as shown by Table 1. DO NOT locate this heat-

er in an area where combustible vapors, gases liquids, or excessive

lint, dust or moisture is present.

Specific to KT Series:

The KT heater is intended for a toe space installation only. Other

grilles are available for a flush surface mount installation that will

trim out the wall can. The heater is designed to be installed in the

toe-space of a cabinet with a minimum of 2” overhang to maximum

7” of overhang. Shorter overhangs may overheat the floor where

longer than 7” overhangs may overheat the cabinet door area.

The wire and breaker sizing chart will give a general rule of installa-

tion size. Consult an electrician if you are not knowledgeable about

wiring codes.

Wire and Breaker Sizing:

Table 2





WIRING: Branch Circuit Connection

1. Connect heater only to the voltage, amperage and frequency

specified on the nameplate.

2. heater only to the voltage, amperage and frequency

specified on the nameplate.

3. Wiring procedures and connections shall be in accordance with

all National and local codes having jurisdiction.

4. Remove the two screws holding the grille in place & set grille

aside retaining the screws.

5. Removing the two screws holding the cover in place on each

side of the heater will allow you access to the wiring compart-

ment.

6. A knockout of 1/2 inch conduit size (7/8 inch / 2.2cm) is pro-

vided in the back and side of the heater for power to enter.

Provide proper conduit connectors for your flexible connec-

tions.

7. Attach ground to the green wire attached to wall case with a

wire nut.

8. Assemble all covers on electrical and apply power. Test unit by

turning thermostat up past room temperature. You will see a

puff of smoke as the elements are energized and the fan turns

on. This is a normal burn off of manufacturing lubricants and

will dissipate in 5 minutes.

9. Heater will continue to run until the room temperature you set

is reached and then turn itself off until the temperature drops

again.

CAUTION - High temperature. Risk of fire, keep electrical

cords, drapery, furnishings, and other combustibles at least 3 feet

(0.9 m) from the front of the heater as well as away from the side

and rear. To reduce the risk of fire, do not store or use gasoline or

other flammable vapors and liquids in the vicinity of the heater.


ELECTRIC SHOCK OR FIRE HAZARD

DANGER

!

!

Figure 2

Figure 4

Factory Wiring Diagram

Figure 5

Minimum Horizontal Clearances

When placed in toe space
of a cabinet only. Horizontal

Min 0”

Max 10”

Depth of

Space

Front

Top

Bottom Sides

Cabinet

Overhang

36 in

0 in

0 in

0 in

91 cm 0 cm

0 cm

0 cm KT Heater

Floor

Figure 3

250 W

500 W

750 W

Hi Switch

LO SW

TABLE 1