Dynamic Brake Module (Part No. 9598) Installation Instructions
Dynamic Brake Module (Part No. 9598) Installation Instructions
Dynamic Brake Module (Part No. 9598) Installation Instructions
Dynamic Brake Module (Part No. 9598) Installation Instructions
(A40148) – Rev. B – 7/18/2006 – Z4181B00
Page 3 of 4
4
4
4
4
KBVF SERIES DRIVES ONLY
KBVF SERIES DRIVES ONLY
KBVF SERIES DRIVES ONLY
KBVF SERIES DRIVES ONLY
In order for the DBM to operate properly with the KBVF Series Drives, the Decel Extend Feature must be disabled. This is accomplished
by installing the jumper (supplied), using long-nose pliers, onto pins 15 and 17 of CON3, as shown in Figure 3.
Disconnect main power when installing this jumper.
When installing the optional SIVFR Signal Isolator and Run/Fault Relay (Part No. 9597) in addition to the Dynamic Brake Module, do not
install the jumper on CON3, shown in Figure 3. The connector will be occupied by the End Connector of the Ribbon Cable which is used
to interface the SIVFR to the KBVF Series Drive. Set Jumper J5, on the SIVFR, to the “DBM” position. See Figure 4.
Figure 3
Jumper (Supplied) Installed on CON3 Pins 15 and 17
(KBVF Series Drives Only)
Figure 4
Jumper J5 on the SIVFR
SIVFR Set for No DBM
(Factory Setting)
(J5 Installed in “NDBM” Position)
SIVFR Set for DBM
(J5 Installed in “DBM” Position)
5
5
5
5
KBBL SERIES DRIVES ONLY
KBBL SERIES DRIVES ONLY
KBBL SERIES DRIVES ONLY
KBBL SERIES DRIVES ONLY
Setting Selectable Jumpers and Calibrating the Drive
The KBBL Series Drives with Hall Isolator Board have customer selectable jumpers which must be set before the DBM can be used. For
the location of the jumpers, see Figures 5 and 6.
In order for the DBM to operate properly, the Decel Extend Feature must be disabled on the KBBL Series Drives, as described in Section
5.1, on page 4. To setup and calibrate the KBBL Series Drive for use with the DBM, see Section 5.2, on page 4.
Figure 5
Expanded View of KBBL Series Drive Jumpers and Trimpots
Figure 6
Expanded View of Hall Isolator Board Jumpers and Trimpots