0 maintenance & handling – Harrington Hoists and Cranes MR Trolley - (MR2) User Manual
Page 44

6.0 Maintenance & Handling
6.1
Count/Hour Meter (Dual Speed Only)
6.1.1
Dual Speed
On dual speed trolleys, the VFD has a Count/Hour function built into the parameters. Refer to
Table 6-1 for parameter identification. Refer to Table 6-2 for Count/Hour access procedure.
Table 6-1 VFD Count/Hour Parameter Identification
Parameter
Name
Discription
U7-01
Number of Starts
(Higher Order)
The number of starts in the down direction x 1,000. Up to 10,000 units are displayed.
Display of “1” = 1,000 starts.
Display of “10,000” = 10,000,000 starts
U7-02
Number of Starts
(Lower Order)
The number of starts in the down direction under 1,000 starts (1 to 999). One start
will register a “1” in the display. When 1,000 starts are reached, the value of U7-01 is
incremented by 1 and the value of U7-02 is reset to 0.
U7-03
Hours of
Operation
The number of hours of operation in both the up and down directions. One hour will
register a “1” in the display. Up to 65535 hours are displayed.
Example using Table 6-1:
•
U7-01 displays “81”, U7-02 displays “567”, U7-03 displays “122”
•
Number of Starts (down) = 81,567
•
Number of Operated Hours = 122
Table 6-2 VFD Count/Hour Access Procedure
Operational Step
VFD Display
1. Energize the hoist.
2. Press
until the “Monitor” screen is displayed (blinking).
3. Press
to display the parameter setting screen an then press
to move from
“01” to “U1”.
4. Press
or
until the display reads “U7” (left value blinking).
5. Press
and
or
to select the specific “Monitor” parameter (right vlaue
blinking).
(Example: U7-03 –Hours of Operation)
6. Press
to display the current parameter value.
(Example: 75 Hours)
7. Press
until the diplay returns to the initial screen.
(As in Step 1.)