beautypg.com

St55gf-manual-5.pdf – SilverStone ST55GF Manual User Manual

Page 6

background image

3.4 Capacitive Loading

The power supply shall be stable and meet all requirements, except dynamic loading
requirements, with the following capacitive loading ranges.

Table 9 - Capacitive Loading Conditions

3.5 Timing Requirements

These are the timing requirements for the power assembly operation. The output voltages
must rise from 10% to within regulation limits (Tvout_rise) within 5 to 200mS. The +5V,
+3.3V and +12V output voltages should start to rise at about the same time. All outputs
must rise monotonically. The +5V output needs to be greater than the +3.3V output during
any point of the voltage rise. The +5V output must never be greater than the +3.3V output
by more than 2.25V. Each output voltage shall reach regulation within 50 mS (Tvout_on) of
each other during turn on of the power supply. Each output voltage shall fall out of
regulation within 400 mS (Tvout_off) of each other during turn off. Figure 1 and figure 2
show the turn On and turn Off timing requirement. In Figure 2, the timing is shown with
both AC and PSON# controlling the On/Off of the power supply.

Table 10 - Output Voltage Timing

Output

MIN

MAX

Units

uF

uF

+5V

+12V

+12V

+5VSB

+3.3V

10

10

1

1

10

uF

12,000

12,000

11,000

350

350

uF

uF

mS

Item

rin

Units

MIN

MAX

Tvout_rise

5

70

mS

Tvout_on

50

mS

Tvout_off

Output voltage rise time from each main output.(+5Vsb < 70mS)

All main output must be within regulation of
each other within this time.

All main output must leave regulation within this time

400

05