2.9 Electrical Discharge, IEC61000-4-2

In addition to IEC61000-4-2, the following ESD tests should be conducted. Each surface
area of the unit under test should be subjected to twenty (20) successive static discharges, at
each of the follow voltages: 2KV, 3KV, 4KV, 5KV, 6KV and 8KV.

All power supply outputs shall continue to operate within the parameters of this
specification, without glitches or interruption, while the power is operating as defined and
subjected to 2kV through 10kV ESD pulses. The direct ESD event shall not cause any out of
regulation conditions such as overshoot or undershoot. The power supply shall withstand
these shocks without nuisance trips of the Over-Voltage Protection, Over-Current Protection,
or the remote +5VDC, +12VDC shutdown circuitry.

2.10Radiated Immunity, IEC61000-4-3

3. DC Output Specification

3.1 Output Current / Loading

The following tables define two power and current rating. The power supply shall
meet both static and dynamic voltage regulation requirements for minimum load
condition.

Table 5 - Load Range 1

Note 1: The +5 & +3.3 Volt total output shall not exceed 180 W.
Note 2: The +5, +3.3 & +12Volt total output shall not exceed 526W.
Note 3: Maximum continues total DC output power shout not exceed 550W.

Frequency

Electric Field Strength

27 MHz to 500 MHz

un-modulated 3 V/m

Min. Load

0.1A

0A

2A

1A

+5V

+5VSB

+12V

-12V

+3.3V

Output Voltage

2A

1A

41A

1A

30A

24A

Max. Load